Material properties of a
- 1 January 1999
- journal article
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 10 (1) , 1-8
- https://doi.org/10.1023/a:1008828925090
Abstract
A study was carried out to investigate changes in mechanical properties and degradation of self-reinforced fibrillated poly-96L/4D-lactide (SR-PLA96) rods in vitro and in vivo. The viscosity-average molecular weight, Mv, of the intact sterile (gamma irradiated) rods was around 50 000 g mol-1. The SR-PLA96 rods of diameter 1.1 mm by 30 mm and diameter 4.5 mm by 50 mm were immersed in phosphate-buffered saline or implanted in the dorsal subcutis of rabbits. Bending, shear and torsion strength and bending modulus, together with the changes of viscosity and crystallinity, were measured up to 24 wk. The strength values showed only a slight decrease during the follow-up period with the exception of torsion strength, that decreased to 52% of the initial value during 24 wk. There were no statistically significant differences in the strength retention between in vitro and in vivo groups. Crystallinity increased over time, being 46–49% at 24 wk. The Mv of the rods decreased over 50% by 24 wk. These promising results motivated us to continue the studies with the fixation of experimental cortical bone osteotomies with SR-PLA96 intramedullary rods. © 1999 Kluwer Academic PublishersKeywords
This publication has 20 references indexed in Scilit:
- New insights on the degradation of bioresorbable polymeric devices based on lactic and glycolic acidsPublished by Elsevier ,2004
- The burst phenomenon, an animal model simulating the long-term tissue response on PLLA interlocking nailsJournal of Biomedical Materials Research, 1996
- In vivo degradation and biocompatibility study of in vitro pre-degraded as-polymerized polylactide particlesBiomaterials, 1995
- Processing and characterization of absorbable polylactide polymers for use in surgical implantsJournal of Applied Biomaterials, 1994
- Intramedullary nailing of the cortical bone osteotomies in rabbits with self-reinforced poly-l-lactide rods manufactured by the fibrillation methodBiomaterials, 1993
- Poly (l-lactide): a long-term degradation study in vivoPart III. Analytical characterizationBiomaterials, 1993
- Biodegradable implants as intramedullary nails. A survey of recent studies and an introduction to their useClinical Materials, 1992
- Biodegradable self-reinforced composite materials; Manufacturing structure and mechanical propertiesClinical Materials, 1992
- Comparison of in vitro hydrolysis, subcutaneous and intramedullary implantation to evaluate the strength retention of absorbable osteosynthesis implantsBiomaterials, 1990
- Resorbable materials of poly(l-lactide)Biomaterials, 1987