Effects of varying electrode configuration with catheter-mediated defibrillator pulses at the coronary sinus orifice in dogs.
- 1 June 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 73 (6) , 1321-1333
- https://doi.org/10.1161/01.cir.73.6.1321
Abstract
We compared two methods of delivering single damped sine-wave defibrillator pulses to the coronary sinus orifice in 20 dogs. Ten dogs had "unipolar" (coronary sinus to precordial disc) and 10 had "bipolar" (coronary sinus proximal to coronary sinus distal electrode) discharges. Delivered voltage, current, and energy were recorded during each pulse. Electrophysiologic testing was done before and 4 weeks after the procedure. Histologic examination of the atrioventricular groove was done at 1 mm serial sections. For the unipolar configuration a 200 J defibrillator pulse resulted in a peak voltage of 3370 .+-. 125 V, a peak current of 21 .+-. 4 A, and a delivered energy of 254 .+-. 29 J as compared with 3010 .+-. 99 V, 70 .+-. 4 A, and 144 .+-. 18 J, respectively, for the bipolar configuration (p < .001). Three dogs (two with bipolar, one with unipolar pulses) had gross coronary sinus rupture and died from aute pericardial tamponade. In addition, irrespective of electrode configuration, all dogs showed microscopic rupture of the coronary sinus internal elastic membrane. Transmural atrial scarring occurred in all 10 dogs that received a unipolar pulse but in only two dogs that received a bipolar pulse (p = .0004). Unlike the atrium, injury to the left ventricle was limited in both groups. Similarly, injury to the periannular myocardium was inconsistent and not transmural in either group. No significant electrophysiologic changes were observed. With the present technique, unipolar rather than bipolar catheter-mediated defibrillator pulses result in transmural atrial injury that might prevent accessory pathway conduction. Regardless of electrode configuration, high-energy defibrillator pulses consistently cause some degree of coronary sinus rupture, most likely related to a barotraumatic mechanism.This publication has 23 references indexed in Scilit:
- Effect of damped sine-wave shocks on catheter dielectric strengthThe American Journal of Cardiology, 1985
- Sequelae of left ventricular electrical endocardial ablationJournal of the American College of Cardiology, 1985
- Pre-excitation due to accessory sinoventricular connexions associated with coronary sinus aneurysms. A report of two cases.Heart, 1985
- Electrophysiologic and anatomic changes in the atrioventricular junction of dogs after direct-current shocks through tissue fixation cathetersThe American Journal of Cardiology, 1985
- Treatment of tachycardias associated with the Wolff-Parkinson-White syndrome by transvenous electrical ablation of accessory pathways.Heart, 1985
- Attempted nonsurgical electrical ablation of accessory pathways via the coronary sinus in the Wolff-Parkinson-White syndromeJournal of the American College of Cardiology, 1984
- Anatomic and electrophysiologic substrate of the permanent form of junctional reciprocating tachycardiaJournal of the American College of Cardiology, 1984
- Effects of energy delivery via a His bundle catheter during closed chest ablation of the atrioventricular conduction system.Journal of Clinical Investigation, 1983
- Transvenous ablation of the atrioventricular conduction system in dogs: Electrophysiologic and histologic observationsThe American Journal of Cardiology, 1983
- Catheter Technique for Closed-Chest Ablation of the Atrioventricular Conduction SystemNew England Journal of Medicine, 1982