Pluronic F‐127 gel preparation as an artificial skin in the treatment of third‐degree burns in pigs
- 1 September 1987
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 21 (9) , 1135-1148
- https://doi.org/10.1002/jbm.820210907
Abstract
A blinded study was designed to provide qualitative and quantitative evaluation on the possible therapeutic benefits of the use of Pluronic® Polyol F-127 as a substitute skin in standardized third-degree thermal burns. Three separate burns, approximately 1600 mm2, were induced on the shaved backs of young, anesthetized pigs. Each animal served as its own control. One burn site was left untreated while the other two sites were covered with coded preparations of the Pluronic® F-127 gel with additives. Polaroid photographs with a fixed focal-length camera were taken of all burn sites for planimetry analysis. Biopsies taken confirmed that third-degree burns were achieved. The pigs were followed for 30 days. The rate of healing of third-degree thermal burns was significantly accelerated over control sites when treated with Pluronic® Polyol F-127 plus propylene glycol. When the bacteriostatic agent Garamycin was also added, the rate of healing remained significantly better than untreated controls. With the addition of Piracetam, burn wound healing was actually retarded within 30 days, when applied topically. Thus, wound healing was both accelerated and retarded as a function of the particular Pluronic® preparation used to treat specific burn sites. This experimental modulation of wound healing suggests that the non-ionic poloxamer, Pluronic F-127, can significantly enhance the rate of wound healing by some unknown mechanism, possibly by stimulation of epithelial growth factor (EGF).This publication has 13 references indexed in Scilit:
- BurnsNew England Journal of Medicine, 1985
- Improved Survival after Massive BurnsPublished by Wolters Kluwer Health ,1983
- Effect of poloxamer 407 gel on the miotic activity of pilocarpine nitrate in rabbitsInternational Journal of Pharmaceutics, 1982
- Considerations on manufacturing principles of a synthetic burn dressing: A reviewJournal of Biomedical Materials Research, 1982
- The Effect of Occlusive Dressings on the Energy Metabolism of Severely Burned ChildrenAnnals of Surgery, 1981
- In vitro release of lidocaine from pluronic F-127 gelsInternational Journal of Pharmaceutics, 1981
- Evaporative Water Loss in Partial Skin Loss in the First 24 HoursScandinavian Journal of Plastic and Reconstructive Surgery, 1979
- Burn Wound CoveringsBiomaterials, Medical Devices, and Artificial Organs, 1978
- Artifical skin. II. Pluronic F‐127 silver nitrate or silver lactate gel in the treatment of thermal burnsJournal of Biomedical Materials Research, 1972
- Artificial skin I. Preparation and properties of pluronic F‐127 gels for treatment of burnsJournal of Biomedical Materials Research, 1972