An In Vivo Comparison of the Potential for Extravertebral Cement Leak After Vertebroplasty and Kyphoplasty
Top Cited Papers
- 1 October 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Spine
- Vol. 27 (19) , 2173-2178
- https://doi.org/10.1097/00007632-200210010-00018
Abstract
A prospective in vivo study was conducted during the performance of kyphoplasty for the treatment of osteoporotic vertebral compression fractures, comparing extravertebral contrast extravasation with kyphoplasty and vertebroplasty. To determine the frequency and pattern of extravertebral contrast extravasation after intravertebral injection during kyphoplasty and vertebroplasty, which have implications for cement leakage during these procedures. Vertebroplasty involves the injection of cement directly into the cancellous bone of a fractured vertebral body in an attempt to stabilize the fracture. High rates of extravertebral cement leakage have been noted. Injection of contrast into the vertebral body under fluoroscopy has been recommended in an attempt to predict and minimize cement leakage. An alternative procedure, balloon kyphoplasty, involves the percutaneous placement of an inflatable bone tamp into the fractured vertebral body. As the tamp is inflated, vertebral body height is restored and a cavity is created within the vertebral body, allowing for low-pressure cement filling of the cavity. During 20 kyphoplasty surgeries for vertebral compression fractures, contrast studies were performed. Immediately after positioning of an 11-gauge biopsy needle within the midvertebral body, 5 mL of Omnipaque was injected, mimicking vertebroplasty injection. Cinefluoroscopic images were obtained during injection. After bilateral fracture reduction and intravertebral cavity creation using inflatable bone tamps (kyphoplasty), contrast was injected again, mimicking cement injection during kyphoplasty. Scoring of the extravertebral contrast leakage was based on filling of the inferior vena cava and epidural vessels, as well as direct contrast extension through the vertebral cortex. The mean contrast leak scores for vertebroplasty- and kyphoplasty-stage injections were, respectively, 4.3 and 0.8 of 6 (P = 0.0001). The scores for epidural vessel and inferior vena cava filling and transcortical contrast leak each was significantly lower for kyphoplasty- than for vertebroplasty-stage injections (P = 0.0001 each). The findings showed less vascular and transcortical extravasation of injected contrast with kyphoplasty than with vertebroplasty. Although leakage of contrast may not correlate precisely with polymethylmethacrylate leakage, the authors believe this study highlights the relative safety of these procedures.Keywords
This publication has 24 references indexed in Scilit:
- New Technologies in SpineSpine, 2001
- An Ex Vivo Biomechanical Evaluation of a Hydroxyapatite Cement for Use With VertebroplastySpine, 2001
- Acute osteoporotic vertebral collapse: open study on percutaneous injection of acrylic surgical cement in 20 patients.American Journal of Roentgenology, 1999
- Vertebral Fractures and Mortality in Older WomenArchives of internal medicine (1960), 1999
- PERCUTANEOUS VERTEBROPLASTY WITH POLYMETHYLMETHACRYLATERadiologic Clinics of North America, 1998
- Clinical Grading of Spinal Osteoporosis: Quality of Life Components and Spinal Deformity in Women with Chronic Low Back Pain and Women with Vertebral OsteoporosisJournal of Bone and Mineral Research, 1997
- Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up.Radiology, 1996
- Quality of life issues in women with vertebral fractures due to osteoporosisArthritis & Rheumatism, 1993
- A study of complaints and their relation to vertebral destruction in patients with osteoporosisBone and Mineral, 1990
- Relationship of Lung Function to Severity of Osteoporosis in WomenAmerican Review of Respiratory Disease, 1990