Tissue ingrowth into titanium and hydroxyapatite‐coated implants during stable and unstable mechanical conditions
Open Access
- 1 March 1992
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 10 (2) , 285-299
- https://doi.org/10.1002/jor.1100100216
Abstract
Lack of initial mechanical stability of cementless prostheses may be responsible for fibrous tissue fixation of prosthetic components to bone. To study the influence of micromovements on bony ingrowth into titanium alloy (Ti) and hydroxyapatite (HA)‐coated implants, a loaded unstable device producing movements of 500 μm during each gait cycle was developed. Mechanically stable implants served as controls. The implants were inserted into the weight‐bearing regions of all four femoral condyles in each of seven mature dogs. Histological analysis after 4 weeks of implantation showed a fibrous tissue membrane surrounding both Ti and HA‐coated implants subjected to micromovements, whereas variable amounts of bony ingrowth were obtained in mechanically stable implants. The pushout test showed that the shear strength of unstable Ti and HA implants was significantly reduced as compared with the corresponding mechanically stable implants (p < 0.01). However, shear strength values of unstable HA‐coated implants were significantly greater than those of unstable Ti implants (p < 0.01) and comparable to those of stable Ti implants. The greatest shear strength was obtained with stable HA‐coated implants, which was threefold stronger as compared with the stable Ti implants (p < 0.001). Quantitative determination of bony ingrowth agreed with the mechanical test except for the stronger anchorage of unstable HA implants as compared with unstable Ti implants, where no difference in bony ingrowth was found. Unstable HA‐coated implants were surrounded by a fibrous membrane containing islands of fibrocartilage with higher collagen concentration, whereas fibrous connective tissue with lower collagen concentration was predominant around unstable Ti implants. In conclusion, micromovements between bone and implant inhibited bony ingrowth and led to the development of a fibrous membrane. The presence of fibrocartilage and a higher collagen concentration in the fibrous membrane may be responsible for the increased shear strength of unstable HA implants. Mechanically stable implants with HA coating had the strongest anchorage and the greatest amount of bony ingrowth.Keywords
This publication has 33 references indexed in Scilit:
- Macroscopic and Microscopic Evidence of Prosthetic Fixation with Porous-Coated MaterialsClinical Orthopaedics and Related Research, 1988
- A Histologic Comparison of Aseptic Loosening of Cemented, Press-Fit, and Biologic Ingrowth ProsthesesClinical Orthopaedics and Related Research, 1987
- In vitro effects of calcium phosphate biomaterials on fibroblastic cell behaviorBiology of the Cell, 1987
- The influence of mechanical conditions on the healing of experimental fractures in the rabbit: a microscopical studyPhilosophical Transactions of the Royal Society of London. B, Biological Sciences, 1986
- The effects of mechanical stability on the macromolecules of the connective tissue matrices produced during fracture healing. I. The collagensJournal of Molecular Histology, 1986
- Bone ingrowth into weight‐bearing porous fiber titanium implants. Mechanical and biochemical correlationsJournal of Orthopaedic Research, 1986
- Approaches to the Interface Problem in Total Joint ArthroplastyClinical Orthopaedics and Related Research, 1984
- Mechanical properties of the fibrous tissue found at the bone‐cement interface following total joint replacementJournal of Biomedical Materials Research, 1982
- Radiographic and Morphologic Studies of Load-Bearing Porous-Surfaced Structured ImplantsClinical Orthopaedics and Related Research, 1981
- Characteristics of tissue growth into proplast and porous polyethylene implants in boneJournal of Biomedical Materials Research, 1979