Rate nephelometric determination of rheumatoid factor: comparison between Kallestad QM-300 and Beckman ICS-II (RF) methods.
- 1 March 1990
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 43 (3) , 243-245
- https://doi.org/10.1136/jcp.43.3.243
Abstract
The Kallestad Corporation recently suggested that their new buffer system for the nephelometric detection of rheumatoid factor conferred advantages over existing systems. Two rate nephelometric procedures, the Kallestad QM-300 and the Bechman, ICS-II (RF), were therefore compared. Sera (n = 157) were selected on the basis of a previous ICS-II value. The results on the QM-300 of sera with an initial rheumatoid factor value of < 400 IU identified two groups. Group 1 (n = 109) showed a good correlation with the ICS-II method while group 2 (n = 13) was highly discordant with the QM-300, producing significantly higher values. The values of 35 sera with an initial rheumatoid factor of > 400 IU were likewise highly discordant, with the QM-300 producing significantly lower values. Dilution recovery experiments implied that the Beckman buffer was likely to be contributory. As the formulae of the buffers remain proprietary, the reasons for the differences are speculative. The findings could be taken to indicate that the Kallestad value is a more accurate indicator of the quantity of rheumatoid factor than the Beckman value.Keywords
This publication has 17 references indexed in Scilit:
- The american rheumatism association 1987 revised criteria for the classification of rheumatoid arthritisArthritis & Rheumatism, 1988
- SEAPAL quality control analysis of rheumatoid factor measurement in 29 diagnostic laboratories.Annals of the Rheumatic Diseases, 1987
- Clinical value of ELISA assays for IgM and IgG rheumatoid factors.Journal of Clinical Pathology, 1987
- Routine quantification of rheumatoid factor by rate nephelometry.Annals of the Rheumatic Diseases, 1985
- Measurement of rheumatoid factors by an enzyme-linked immunosorbent assay (ELISA) and comparison with other methods.Annals of the Rheumatic Diseases, 1985
- RESULTS OF TESTS FOR RHEUMATOID-FACTOR ON CAP SURVEY SPECIMENS1983
- Performance of a new rate-nephelometric assay for rheumatoid factor, and its correlation with tube-titer results for human sera and synovial fluid.Clinical Chemistry, 1982
- A simple radioactive binding assay for the detection of rheumatoid factor in serumJournal of Immunological Methods, 1980
- Rheumatoid factor detection by nephelometryArthritis & Rheumatism, 1980
- ON THE OCCURRENCE OF A FACTOR IN HUMAN SERUM ACTIVATING THE SPECIFIC AGGLUTINATION OF SHEEP BLOOD CORPUSCLES.Acta Pathologica Microbiologica Scandinavica, 1940