Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents
- 25 January 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 111 (3) , 321-327
- https://doi.org/10.1161/01.cir.0000153356.72810.97
Abstract
Background— Observed rates of restenosis after drug-eluting stenting are low (Methods and Results— Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17±0.45 mm (sirolimus) versus 1.00±0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665). Conclusions— Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.Keywords
This publication has 30 references indexed in Scilit:
- Quantitative Assessment of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Native Coronary ArteriesCirculation, 2004
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Comparison of rotational atherectomy with conventional balloon angioplasty in the prevention of restenosis of small coronary arteries: Results of the Dilatation vs Ablation Revascularization Trial Targeting Restenosis (DART)American Heart Journal, 2003
- Application of models for multivariate mixed outcomes to medical device trials: coronary artery stentingStatistics in Medicine, 2002
- Influence of stent design on 1-year outcome after coronary stent placement: A randomized comparison of five stent types in 1,147 unselected patientsCatheterization and Cardiovascular Interventions, 2000
- A new approach for the quantification of complex lesion morphology: The gradient field transform; Basic principles and validation resultsJournal of the American College of Cardiology, 1994
- Is 40% to 70% diameter narrowing at the site of previous stenting or directional coronary atherectomy clinically significant?The American Journal of Cardiology, 1994
- Generalized model of restenosis after conventional balloon angioplasty, stenting and directional atherectomyJournal of the American College of Cardiology, 1993
- Novel approach to the analysis of restenosis after the use of three new coronary devicesJournal of the American College of Cardiology, 1992
- Lumen narrowing after percutaneous transluminal coronary balloon angioplasty follows a near gaussian distribution: A quantitative angiographic study in 1,445 successfully dilated lesionsJournal of the American College of Cardiology, 1992