Abstract
The electron excitation cross section of the metastable level of neon is measured by a new technique that involves laser excitation of the metastables to a fluorescing level. A method for obtaining an absolute calibration of the cross section is given. The value of the direct cross section is 16× at 20 eV energy of the incident electrons.
Keywords
This publication has 3 references indexed in Scilit:
- Opto-galvanic spectroscopy of a neon discharge: Mechanism studiesChemical Physics Letters, 1978
- Simultaneous Ionization and Excitation of Neon by Electron ImpactPhysical Review A, 1972