A biplanar image-matching technique was developed and applied to a study of normal knee kinematics in vivo under weightbearing conditions. Three-dimensional knee models of six volunteers were constructed using computed tomography. Projection images of the models were fitted onto anteroposterior and lateral radiographs of the knees at hyperextension and every 15° from 0° to 120° flexion. Knee motion was reconstructed on the computer. The femur showed a medial pivoting motion relative to the tibia during knee flexion, and the average range of external rotation associated with flexion was 29.1°. The center of the medial femoral condyle translated 3.8 mm anteriorly, whereas the center of the lateral femoral condyle translated 17.8 mm posteriorly. This rotational motion, with a medially offset center, could be interpreted as a screw home motion of the knee around the tibial knee axis and a posterior femoral rollback in the sagittal plane. However, the motion of the contact point differed from that of the center of the femoral condyle when the knee flexion angle was less than 30°. Within this range, medial and lateral contact points translated posteriorly, and a posterior femoral rollback occurred. This biplanar image-matching technique is useful for investigating knee kinematics in vivo.Keywords
This publication has 24 references indexed in Scilit:
- In Vivo Anteroposterior Femorotibial Translation of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- The Transepicondylar Axis Approximates the Optimal Flexion Axis of the KneeClinical Orthopaedics and Related Research, 1998
- In vivo kinematics of cruciate-retaining and -substituting knee arthroplastiesThe Journal of Arthroplasty, 1997
- In Vivo Knee Kinematics Derived Using an Inverse Perspective TechniqueClinical Orthopaedics and Related Research, 1996
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Motion of the knee after condylar resurfacing—An in vivo studyJournal of Biomechanics, 1991
- A Correlative Study of the Geometry and Anatomy of the Distal FemurPublished by Wolters Kluwer Health ,1990
- Interaction between intrinsic knee mechanics and the knee extensor mechanismJournal of Orthopaedic Research, 1987
- A Joint Coordinate System for the Clinical Description of Three-Dimensional Motions: Application to the KneeJournal of Biomechanical Engineering, 1983
- Biomechanics of Internal Derangement of the KneeJournal of Bone and Joint Surgery, 1971