Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man.
- 1 July 1981
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 64 (1) , 146-152
- https://doi.org/10.1161/01.cir.64.1.146
Abstract
Changes in the capacitance vasculature influence venous return and cardiac performance, so an understanding of the effects of pathophysiologic states on the human capacitance vasculature is necessary to understand integrated cardiovascular function in man. Techniques available to assess the capacitance vasculature in man, however, have limitations. We performed radionuclide imaging of the calf or forearm in 51 patients whose erythrocytes had been labeled in vivo with technetium-99m, basing our approach on the principle that counts from the radiolabeled intravascular space are proportional to blood volume. Two-minute or 15 second count acquisitions were obtained from the calf in 42 patients. Counts obtained at rest demonstrated little variation. With veno-occlusion at 15 and 30 mm Hg, counts increased 8 +/- 1% (+/- SEM) (p less than 0.001) and 28 +/- 2% (p less than 0.001), respectively. After 0.4 mg of sublingual nitroglycerin, counts increased 9 +/- 1% (p less than 0.001). With leg elevation, counts decreased 34 +/- 4% (p less than 0.001). Response patterns were similar with 2-minute and 15-second acquisitions. In nine patients who underwent forearm imaging (2-minute acquisitions), counts increased 14 +/- 2% (p less than 0.001) and 26 +/- 4% (p less than 0.001) at 15- and 30-mm Hg veno-occlusion and 15 +/- 3% (p less than 0.001) after nitroglycerin. Volume displacements, recorded simultaneously with a fluid-filled plethysmograph about the contralateral forearm, correlated linearly in all nine patients. Thus, gamma camera imaging of the radiolabeled peripheral intravascular space provides a quantitative and reliable assessment of peripheral vascular capacity in man. The technique could be used in conjunction with gated cardiac imaging in order to assess the interactions of peripheral vascular capacity and ventricular performance.This publication has 11 references indexed in Scilit:
- A miniature cadmium telluride detector module for continuous monitoring of left-ventricular function.Radiology, 1981
- Of linens and laces—The eighth anniversary of the gated blood pool scanSeminars in Nuclear Medicine, 1979
- Radionuclide-Determined Change in Pulmonary Blood Volume with ExerciseNew England Journal of Medicine, 1979
- A scintiphotographic method for measuring left ventricular ejection fraction in man without cardiac catheterizationThe American Journal of Cardiology, 1971
- Simplified method for measuring compliance of superficial veinsCardiovascular Research, 1971
- METHODS FOR THE INVESTIGATION OF PERIPHERAL BLOOD FLOWBritish Medical Bulletin, 1963
- The distensibility of the blood vessels of the human calf determined by graded venous congestionThe Journal of Physiology, 1958
- A study of the venomotor tone in a short intact venous segment of the forearm of manAmerican Heart Journal, 1956
- The measurement of volume changes in human limbsThe Journal of Physiology, 1953
- A critique of the plethysmographic method of measuring blood flow in the extremities of manAmerican Heart Journal, 1942