A Chronoamperometric Method To Estimate Ionophore Loss from Ion-Selective Electrode Membranes
- 20 July 1999
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 71 (17) , 3673-3676
- https://doi.org/10.1021/ac990137b
Abstract
A novel chronoamperometric method was developed to estimate the concentration of a neutral ionophore in fixed-site, dioctyl sebacate plasticized, poly(vinyl chloride)-based, ion-selective electrode membranes. The membranes contained between 0.5 and 16 mmol/kg valinomycin. The chronoamperometric technique was used to estimate the valinomycin concentration in freshly prepared membranes and after extraction of some of the ionophore from the membranes using dioctyl sebacate. Replicate measurements indicated a relative standard deviation in the calculated valinomycin concentration of less than 10%, and these values accurately represented the true concentration of valinomycin within 10%. The method permitted an estimate of the valinomycin concentration after valinomycin was leached from a membrane. The results of preliminary experiments using heparinized dog blood suggest that blood protein adsorption does not interfere qualitatively or quantitatively with the analysis.Keywords
This publication has 11 references indexed in Scilit:
- Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General CharacteristicsChemical Reviews, 1997
- Optimum composition of neutral carrier based pH electrodesAnalytica Chimica Acta, 1994
- Planar micro sensors for in vivo myocardial pH measurementsTalanta, 1994
- Characterization of Stability of Modified Poly(vinyl chloride) Membranes for Microfabricated Ion-Selective Electrode Arrays in Biomedical ApplicationsPublished by American Chemical Society (ACS) ,1994
- Transport processes in membranes containing neutral ion carriers, positive ion complexes, negative mobile sites, and ion pairsThe Journal of Physical Chemistry, 1993
- In vivo and in vitro testing of microelectronically fabricated planar sensors designed for applications in cardiologyAnalytical and Bioanalytical Chemistry, 1993
- Selectivity-modifying influence of anionic sites in neutral-carrier-based membrane electrodesAnalytical Chemistry, 1991
- Lifetime of neutral-carrier-based liquid membranes in aqueous samples and blood and the lipophilicity of membrane componentsAnalytical Chemistry, 1991
- Evaluation of the optimum composition of neutral-carrier membrane electrodes with incorporated cation-exchanger sitesAnalytica Chimica Acta, 1984
- Lifetime of neutral carrier based ion-selective liquid-membrane electrodesAnalytical Chemistry, 1980