Measuring tortuosity of the intracerebral vasculature from MRA images
Top Cited Papers
- 4 September 2003
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 22 (9) , 1163-1171
- https://doi.org/10.1109/tmi.2003.816964
Abstract
The clinical recognition of abnormal vascular tortuosity, or excessive bending, twisting, and winding, is important to the diagnosis of many diseases. Automated detection and quantitation of abnormal vascular tortuosity from three-dimensional (3-D) medical image data would, therefore, be of value. However, previous research has centered primarily upon two-dimensional (2-D) analysis of the special subset of vessels whose paths are normally close to straight. This report provides the first 3-D tortuosity analysis of clusters of vessels within the normally tortuous intracerebral circulation. We define three different clinical patterns of abnormal tortuosity. We extend into 3-D two tortuosity metrics previously reported as useful in analyzing 2-D images and describe a new metric that incorporates counts of minima of total curvature. We extract vessels from MRA data, map corresponding anatomical regions between sets of normal patients and patients with known pathology, and evaluate the three tortuosity metrics for ability to detect each type of abnormality within the region of interest. We conclude that the new tortuosity metric appears to be the most effective in detecting several types of abnormalities. However, one of the other metrics, based on a sum of curvature magnitudes, may be more effective in recognizing tightly coiled, "corkscrew" vessels associated with malignant tumors.Keywords
This publication has 31 references indexed in Scilit:
- Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extractionIEEE Transactions on Medical Imaging, 2002
- Symbolic description of intracerebral vessels segmented from magnetic resonance angiograms and evaluation by comparison with X-ray angiogramsMedical Image Analysis, 2001
- Artery-vein separation via MRA-An image processing approachIEEE Transactions on Medical Imaging, 2001
- Model-Based Detection of Tubular Structures in 3D ImagesComputer Vision and Image Understanding, 2000
- Model-based quantitation of 3-D magnetic resonance angiographic imagesIEEE Transactions on Medical Imaging, 1999
- An adaptive segmentation algorithm for time-of-flight MRA dataIEEE Transactions on Medical Imaging, 1999
- MRI and angiographic diagnosis of lupus cerebral vasculitisNeuroradiology, 1996
- A NUMERIC INDEX BASED ON SPATIAL FREQUENCY FOR THE TORTUOSITY OF RETINAL VESSELS AND ITS APPLICATION TO PLUS DISEASE IN RETINOPATHY OF PREMATURITYRetina, 1995
- The detection and quantification of retinopathy using digital angiogramsIEEE Transactions on Medical Imaging, 1994
- Two-Dimensional Tortuosity of the Superficial Femoral Artery in Early AtherosclerosisJournal of Vascular Research, 1993