Detection of Simulated Interstitial Lung Disease and Catheters with Selenium, Storage Phosphor, and Film-based Radiography
- 1 November 1999
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 213 (2) , 445-454
- https://doi.org/10.1148/radiology.213.2.r99nv20445
Abstract
To evaluate the diagnostic performance of storage phosphor and digital selenium radiography (DSR) with asymmetric and symmetric screen-film systems at different speeds in the detection of simulated interstitial lung disease and catheters. Patterns of simulated interstitial lung disease and catheters were superimposed over an anthropomorphic chest phantom. Hard-copy images were generated at DSR (200-, 400-, and 600-speed), storage phosphor radiography (200- and 400-speed), and asymmetric (400-speed) and symmetric (200- and 400-speed) screen-film imaging. Surface doses were measured, and receiver operating characteristic analyses were performed. No statistically significant differences were found between the detector systems with the same speeds for each interstitial pattern. Significantly poorer results were found at 600-speed DSR than at 200-speed DSR. Detection of catheters and nodules over high-attenuation areas was significantly worse with the symmetric screen-film system than with the other detectors. The surface dose with the DSR system, without a grid, was about 50% less than that of the other detector systems, with grids, at the same speed. No significant difference was found in the diagnostic performance at DSR, storage phosphor radiography, and film-based radiography for simulated interstitial lung disease at corresponding speeds; there was a reduction in the surface dose of about 50% with the 400-speed DSR system.Keywords
This publication has 20 references indexed in Scilit:
- Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.Radiology, 1996
- Effects of dose reduction on digital chest imaging using a selenium detector: a study of detecting simulated diffuse interstitial pulmonary disease.American Journal of Roentgenology, 1996
- ROC-Analysis of Detection Performance by Analogue and Digital Plain Film Systems in Chest RadiographyActa Radiologica, 1996
- Phantom Study of Chest Radiography with Storage Phosphor, Selenium, and Film-Screen SystemsActa Radiologica, 1996
- Digital Chest Imaging Using a Selenium DetectorInvestigative Radiology, 1995
- Detection of simulated chest lesions: comparison of a conventional screen-film combination, an asymmetric screen-film system, and storage phosphor radiography.Radiology, 1995
- Image quality of a digital chest radiography system based on a selenium detectorMedical Physics, 1994
- Wertigkeit des asymmetrischen Film-Folien-Systems InSight HC in der ThoraxdiagnostikRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1994
- Improved parameters for unsharp mask filtering of digital chest radiographs.Radiology, 1993
- Grids or air gaps for scatter reduction in digital radiography: A model calculationMedical Physics, 1992