Porous, Resorbable, Fiber-Reinforced Scaffolds Tailored for Articular Cartilage Repair
- 1 December 2001
- journal article
- research article
- Published by Mary Ann Liebert Inc in Tissue Engineering
- Vol. 7 (6) , 767-780
- https://doi.org/10.1089/107632701753337717
Abstract
Porous 75:25 poly(D,L-lactide-co-glycolide) scaffolds reinforced with polyglycolide fibers were prepared with mechanical properties tailored for use in articular cartilage repair. Compression testing was performed to investigate the influence of physiological testing conditions, manufacturing method, anisotropic properties due to predominant fiber orientation, amounts of fiber reinforcement (0 to 20 wt, %), and viscoelasticity via a range of strain rates. Using the same testing modality, the mechanical properties of the scaffolds were compared with pig and goat articular cartilage. Results showed that mechanical properties of the scaffolds under physiological conditions (aqueous, 37°C) were much lower than when tested under ambient conditions. The manufacturing method and anisotropy of the scaffolds significantly influenced the mechanical properties. The compressive modulus and yield strength proportionally increased with increasing fiber reinforcement up to 20%. From 0.01 to 10 mm/mm/min strain rate, the compressive modulus increased in a logarithmic fashion, and the yield strength increased in a semi-log fashion. The compressive modulus of the non-reinforced scaffolds was most similar to the pig and goat articular cartilage when compared using similar testing conditions and modality, but the improvement in yield strength using the stiffer scaffolds with fiber reinforcement could provide needed structural support for in vivo loads.Keywords
This publication has 46 references indexed in Scilit:
- Open pore biodegradable matrices formed with gas foamingJournal of Biomedical Materials Research, 1998
- Salient Degradation Features of a 50:50 PLA/PGA Scaffold for Tissue EngineeringTissue Engineering, 1996
- The Effects of Dynamic Compressive Loading on Biodegradable Implants of 50–50% Polylactic Acid–Polyglycolic AcidTissue Engineering, 1996
- Fabrication of biodegradable polymer scaffolds to engineer trabecular boneJournal of Biomaterials Science, Polymer Edition, 1996
- Engineering New Tissue: Formation of Neo-CartilageTissue Engineering, 1995
- Tissue Engineering: Biomedical ApplicationsTissue Engineering, 1995
- Hydroxylapatite supported Dacron plugs for repair of isolated full‐thickness osteochondral defects of the rabbit femoral condyle: Mechanical and histological evaluations from 6–48 weeksJournal of Biomedical Materials Research, 1993
- Indentation assessment of biphasic mechanical property deficits in size-dependent osteochondral defect repairJournal of Biomechanics, 1993
- Porous polymer implants for repair of full-thickness defects of articular cartilage: An experimental study in rabbit and dogBiomaterials, 1992
- Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and ExperimentsJournal of Biomechanical Engineering, 1980