CHOOSING AN APPROPRIATE CUTTING POINT FOR CONVERSION IN ANNUAL TUBERCULIN SKIN TESTING
- 1 January 1985
- journal article
- research article
- Published by Elsevier
- Vol. 132 (2) , 379-381
- https://doi.org/10.1164/arrd.1985.132.2.379
Abstract
The use of a 2-step tuberculin testing program in new employees reduced the apparent rate of conversion in annual skin testing by eliminating the effect of the booster phenomenon. The converter rate subsequently remained too high. The use of 10 mm of induration as the cutting point apparently gave a high rate of false conversion in our area of high prevalence of sensitivity to nontuberculous mycobacteria. A change to 15 mm of duration as the cutting point reduced conversion rate from 2.6-1.2%, identified a group who demonstrated continued large tuberculin reactions at repeat testing, and eliminated age dependency from the converter population. The choice of 15 mm of induration is proposed as the appropriate cutting point in annual employees tuberculin skin testing programs in areas in which sensitivity to nontuberculous mycobacteria is common.This publication has 4 references indexed in Scilit:
- BOOSTER PHENOMENON IN SERIAL TUBERCULIN TESTINGPublished by Elsevier ,1979
- ANAMNESTIC EFFECT IN TUBERCULIN SKIN TESTING - MEASUREMENT AND TIME RELATIONS - EXPERIMENTS IN BCG-VACCINATED GUINEA-PIGS1978
- ANALYSIS OF A COMMUNITY-HOSPITAL EMPLOYEE TUBERCULOSIS SCREENING-PROGRAM 31 MONTHS AFTER ITS INCEPTIONPublished by Elsevier ,1977
- FRESH LOOK AT DEFINITION OF TUBERCULOUS INFECTION AND NEW INFECTION1976