Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling
- 1 January 1993
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 59 (1) , 219-226
- https://doi.org/10.1128/aem.59.1.219-226.1993
Abstract
Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments.Keywords
This publication has 15 references indexed in Scilit:
- Inhaled Endotoxin and Decreased Spirometric ValuesNew England Journal of Medicine, 1987
- Occurrence of moulds in modern living and working environmentsEuropean Journal of Epidemiology, 1985
- Performance of the surface air system air samplersJournal of Hospital Infection, 1985
- Bacterial endotoxin isolated from a water spray air humidification system as a putative agent of occupation-related lung diseaseInfection and Immunity, 1984
- Fungi as a Cause of Allergic DiseaseAllergy, 1979
- Comparative recoveries of airborne fungus spores by viable and non-viable modes of volumetric collectionMycopathologia, 1977
- A review of respiratory virology and the spread of virulent and possibly antigenic viruses via air conditioning systems. I.1973
- Clinical sensitivity to green algae demonstrated by nasal challenge and in vitro tests of immediate hypersensitivityJournal of Allergy and Clinical Immunology, 1973
- Hospital Airborne Bacteria as Estimated by the Andersen Samplerversusthe Gravity Settling Culture PlateAmerican Journal of Clinical Pathology, 1972
- Estimation of airborne fungal flora by the Andersen sampler versus the gravity settling culture plate: I. Isolation frequency and numbers of coloniesJournal of Allergy, 1969