Comparison between electric evoked potentials, source dipole components and magnetic evoked fields elicited by noise/square-wave stimuli
- 1 October 1988
- journal article
- research article
- Published by Hindawi Limited in Acta Neurologica Scandinavica
- Vol. 78 (4) , 337-345
- https://doi.org/10.1111/j.1600-0404.1988.tb03666.x
Abstract
The aim of this study was to compare auditory evoked electric potentials (AEPs), source dipole components calculated from AEPs, and auditory evoked magnetic fields (AEFs). Noise/square-wave stimuli were presented either to the left or to the right ear. AEPs were measured from sclap electrodes on a coronal plane and AEFs were recorded over frontotemporal regions of both hemispheres. An increase of the ISI from 2 to 4-6 s did not change the scalp topography of AEPs nor the ratio of the tangential and radial source componentes. The 100-ms deflections of AEFs were higher in amplitude and shorter in latency to contra- than ipsilateral stimuli; a similar behaviour was seen in the tangential source components of AEPs. The similarity of the tangential components and the magnetic responses suggests that the method to calculate source dipole components can be useful in differentiating between the hemispheric differences in the activation of the auditory cortices and in discerning the tangential and the radial sources.Keywords
This publication has 17 references indexed in Scilit:
- Contra- and ipsilateral auditory stimuli produce different activation patterns at the human auditory cortexPflügers Archiv - European Journal of Physiology, 1988
- Modification of neuromagnetic responses of the human auditory cortex by masking soundsExperimental Brain Research, 1988
- Responses of the human auditory cortex to vowel onset after fricative consonantsExperimental Brain Research, 1987
- Large-area low-noise seven-channel dc SQUID magnetometer for brain researchReview of Scientific Instruments, 1987
- Neuromagnetic Responses of the Human Auditory Cortex to On- and Offsets of Noise Bursts: Réponses neuromagnétiques du cortex auditif humain à l'établissement et l'extinction de salves de bruitInternational Journal of Audiology, 1987
- Cortical magnetic fields evoked by frequency glides of a continuous toneElectroencephalography and Clinical Neurophysiology, 1982
- Interstimulus interval dependence of the auditory vertex response and its magnetic counterpart: Implications for their neural generationElectroencephalography and Clinical Neurophysiology, 1982
- Auditory Magnetic Fields from the Human CortexInfluence of Stimulus IntensityScandinavian Audiology, 1981
- Auditory evoked transient and sustained magnetic fields of the human brain localization of neural generatorsExperimental Brain Research, 1980
- Magnetic Auditory Responses from the Human BrainA Preliminary ReportScandinavian Audiology, 1980