Abstract
The ability of ultrasound to produce highly controlled tissue erosion was investigated. This study is motivated by the need to develop a noninvasive procedure to perforate the neonatal atrial septum as the first step in treatment of hypoplastic left heart syndrome. A total of 232 holes were generated in 40 pieces of excised porcine atrial wall by a 788 kHz single-element transducer. The effects of various parameters [e.g., pulse repetition frequency (PRF), pulse duration (PD), and gas content of liquid] on the erosion rate and energy efficiency were explored. An Isppa of 9000 W/cm2, PDs of 3, 6, 12, and 24 cycles; PRFs between 1.34 kHz and 66.7 kHz; and gas saturation of 40-55% and 79-85% were used. The results show that very short pulses delivered at certain PRFs could maximize the erosion rate and energy efficiency. We show that well-defined perforations can be precisely located in the atrial wall through the controlled ultrasound tissue erosion (CUTE) process. A preliminary in vivo experiment was conducted on a canine subject, and the atrial septum was perforated using CUTE.Keywords
This publication has 21 references indexed in Scilit:
- Distinct Anabolic Response of Osteoblast to Low-Intensity Pulsed UltrasoundJournal of Bone and Mineral Research, 2003
- Thermal dose optimization for ultrasound tissue ablationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999
- Intestinal hemorrhage from exposure to pulsed ultrasoundUltrasound in Medicine & Biology, 1995
- Effects of pulsed ultrasound on the mouse neonate: Hind limb paralysis and lung hemorrhageUltrasound in Medicine & Biology, 1994
- A review of the physical properties and biological effects of the high amplitude acoustic fields used in extracorporeal lithotripsyUltrasonics, 1993
- Lung damage from exposure to pulsed ultrasoundUltrasound in Medicine & Biology, 1990
- Thresholds for cavitation produced in water by pulsed ultrasoundUltrasonics, 1988
- Cavitation threshold measurements for microsecond length pulses of ultrasoundThe Journal of the Acoustical Society of America, 1988
- A mechanism for the generation of cavitation maxima by pulsed ultrasoundThe Journal of the Acoustical Society of America, 1984
- Pulsed enhancement of acoustic cavitation: A postulated modelUltrasound in Medicine & Biology, 1981