Normal Variability of Static Perimetric Threshold Values Across the Central Visual Field
- 1 November 1987
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 105 (11) , 1544-1549
- https://doi.org/10.1001/archopht.1987.01060110090039
Abstract
• We assessed the variability of results in normal subjects of computerized static threshold perimetry of the central 30° field. Variability of measured threshold values was highly dependent on eccentricity. This included variability among individuals, test-to-test variability within individuals, and intratest variability. All values were significantly larger in the midperiphery than centrally. We found that the mean sensitivity decrement with age was eccentricity dependent, so that the age-corrected normal visual field became not only depressed but also steeper with age. Distributions of individual pointwise deviations from the agecorrected normal mean thresholds were significantly nongaussian. The dependency of variability on test point location, the nongaussian distributions of deviations from age-corrected means, and the variability of age-induced sensitivity reduction should all be considered in the interpretation of computerized visual fields, and particularly in the design of statistical programs for field analysis. Programs not considering these factors are likely to result in misleading analyses.This publication has 14 references indexed in Scilit:
- The Normal Visual Field on the Humphrey Field AnalyzerOphthalmologica, 1986
- Asymmetry and Variation in the Normal Hill of VisionArchives of Ophthalmology (1950), 1986
- Probability Maps for Evaluating Automated Visual FieldsDocumenta Ophthalmologica Proceedings Series, 1985
- The Humphrey Field Analyzer: Concepts and Clinical ResultsPublished by Springer Nature ,1985
- Variation in Visual Field Measurements with an Automated PerimeterAmerican Journal of Ophthalmology, 1984
- Automatic (Octopus) and manual (Goldmann) perimetry in glaucomaAlbrecht von Graefes Archiv für Ophthalmologie, 1980
- Threshold Fluctuations, Interpolations and Spatial Resolution in PerimetryPublished by Springer Nature ,1979
- COMPUTER TEST LOGICS FOR AUTOMATIC PERIMETRYActa Ophthalmologica, 1977
- STATIC PERIMETRY: ACCURACY AND FLUCTUATIONSActa Ophthalmologica, 1976
- Studies on the Effects of Age on the Central and Peripheral Isopters of the Visual Field in Normal SubjectsAmerican Journal of Ophthalmology, 1967