Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
Top Cited Papers
- 1 February 2002
- journal article
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 19 (2) , 246-251
- https://doi.org/10.1183/09031936.02.00218402
Abstract
This study assessed whether the improper use of pressurized metered-dose inhalers (pMDIs) is associated with decreased asthma control in asthmatics treated by inhaled corticosteroids (ICS). General practitioners (GPs) included consecutive asthmatic outpatients treated by pMDI-administered ICS and on-demand, short-acting β2-agonists. They measured an asthma instability score (AIS) based on daytime and nocturnal symptoms, exercise-induced dyspnoea, β2-agonist usage, emergency-care visits and global perception of asthma control within the preceding month; the inhalation technique of the patient also was assessed. GPs (n=915) included 4,078 adult asthmatics; 3,955 questionnaires were evaluable. pMDI was misused by 71% of patients, of which 47% was due to poor coordination. Asthma was less stable in pMDI misusers than in good users (AIS: 3.93 versus 2.86, pversus 3.56 in good coordinators, p<0.001). To conclude, misuse of pressurized metered-dose inhalers, which is mainly due to poor coordination, is frequent and associated with poorer asthma control in inhaled corticosteroid-treated asthmatics. This study highlights the importance of evaluating inhalation technique and providing appropriate education in all patients, especially before increasing inhaled corticosteroid dosage or adding other agents. The use of devices which alleviate coordination problems should be reinforced in pressurized metered-dose inhaler misusers.Keywords
This publication has 8 references indexed in Scilit:
- Development and validation of a questionnaire to measure asthma controlEuropean Respiratory Journal, 1999
- Differences between asthma exacerbations and poor asthma controlThe Lancet, 1999
- Asthma control versus asthma severityJournal of Allergy and Clinical Immunology, 1996
- Improper patient techniques with metered dose inhalers: Clinical consequences and solutions to misuseJournal of Allergy and Clinical Immunology, 1995
- Medical Personnel's Knowledge of and Ability to Use Inhaling DevicesChest, 1994
- Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.Thorax, 1991
- The adult patient’s difficulties with inhalersLung, 1990
- Improvement of pressurised aerosol deposition with Nebuhaler spacer device.Thorax, 1984