Risk-Adjusted Outcome Analysis of Endovascular Abdominal Aortic Aneurysm Repair in a Large Population:How Do Stent-Grafts Compare?
- 1 August 2005
- journal article
- research article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 12 (4) , 417-429
- https://doi.org/10.1583/05-1530r.1
Abstract
Purpose: To compare differences in the applicability and incidence of postoperative adverse events among stent-grafts used for repair of infrarenal aortic aneurysms. Methods: An analysis of 6787 patients from the EUROSTAR Registry database was conducted to compare aneurysm morphological features, patient characteristics, and postoperative events for the AneuRx, EVT/Ancure, Excluder, Stentor, Talent, and Zenith devices versus the Vanguard device (control) and each other. Annual incidence rates of complications were determined, and risks were compared using the Cox proportional hazards analysis. Results: The annual incidence rates were: device-related endoleak (types I and III) 6% (range 4%-10%), type II endoleak 5% (range 0.3%-11%), migration 3% (range 0.5%-5%), kinking 2% (range 1%-5%), occlusion 3% (range 1%-5%), rupture 0.5% (range 0%-1%), and all-cause mortality 7% (range 5%-8%). After adjustment for factors influencing outcome, AneuRx, Excluder, Talent, and Zenith devices were associated with a lower risk of migration, kinking, occlusion, and secondary intervention compared to the Vanguard device. Significant increased risk for conversion (EVT/Ancure) and reduced risk of aneurysm rupture (AneuRx and Zenith) and all-cause mortality (Excluder) were found compared to the Vanguard device. Conclusions: Significant differences exist between stent-grafts of different labels in terms of applicability and complications during intermediate to long-term follow-up. Since each stent-graft has its drawbacks, no single label can be identified as the best. It is reassuring that developments in stent-grafts indeed result in better performance than the early stent-grafts. However, a single device incorporating all the perceived improvements should still be pursued.Keywords
This publication has 29 references indexed in Scilit:
- Late abdominal aortic aneurysm enlargement after endovascular repair with the excluder deviceJournal of Vascular Surgery, 2004
- Variable sac behavior after endovascular repair of abdominal aortic aneurysm: analysis of core laboratory dataJournal of Vascular Surgery, 2004
- Predicting iliac limb occlusions after bifurcated aortic stent grafting: Anatomic and device-related causesJournal of Vascular Surgery, 2002
- The Evolving Technique of Endovascular Stenting of Abdominal Aortic Aneurysm; Time for ReappraisalEuropean Journal of Vascular and Endovascular Surgery, 2001
- The Impact of Stent-graft Development on Outcomeof AAA Repair – a 7-Year ExperienceEuropean Journal of Vascular and Endovascular Surgery, 2001
- An update of the Zenith endovascular graft for abdominal aortic aneurysms: Initial implantation and mid-term follow-up dataJournal of Vascular Surgery, 2001
- Mid-term Results of Endovascular Versus Open Repair for Abdominal Aortic Aneurysm in Patients Anatomically Suitable for Endovascular RepairEuropean Journal of Vascular and Endovascular Surgery, 2000
- Regarding “Problems with the dissemination of up-to-date information on the results of endograft repair for abdominal aortic aneurysm”Journal of Vascular Surgery, 1999
- AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: Multicenter prospective clinical trialJournal of Vascular Surgery, 1999
- Endovascular treatment of infrarenal abdominal aneurysms by the Stentor system: Preliminary results of 79 casesJournal of Vascular Surgery, 1997