Temperature Programming for High-Speed GC
- 28 April 1999
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 71 (11) , 2123-2129
- https://doi.org/10.1021/ac9812936
Abstract
Fast temperature programming (20−50 °C/min) is used with relatively short separation columns to achieve high-speed separations of mixtures covering a wide boiling point range. A cryofocusing inlet is used to obtain narrow injection plugs. High-speed temperature-programmed chromatograms are evaluated by considering local peak capacity as a function of carbon number and boiling point for the normal alkanes in the range C8−C19. The peak capacity generation rate (peaks per second) as a function of carbon number and the total cumulative peak capacity as a function of time are also considered for various column lengths and carrier gas flow rates. Column lengths in the range 3.6−25.4 m and average carrier gas velocity values in the range 50−200 cm/s are considered. For a 6.8-m-long, 0.25-mm-i.d. column operated at an average carrier gas velocity of about 100 cm/s and using a nominal programming rate of 50 °C/min, C19 elutes in 178 s with a total peak capacity of 168 peaks. If the programming rate is reduced to 20 °C/min, the C19 elution time more than doubles but the total peak capacity increases by only 20%. For a 25.4-m-long column using a nominal 50 °C/min programming rate, the C19 retention time is 262 s with a peak capacity of 279 peaks. The use of average carrier gas flow rates greater than about 100 cm/s, which is common in isothermal high-speed GC, results in a considerable loss in total peak capacity with remarkably little reduction in analysis time.Keywords
This publication has 31 references indexed in Scilit:
- Packed Capillary Column Solvating Gas Chromatography Using Mobile Phases That Transition from Liquid to Gas between the Column Inlet and OutletAnalytical Chemistry, 1998
- A modified inlet system for high speed gas chromatography using inert metal tubing with a carbon dioxide cooled cryotrapJournal of High Resolution Chromatography, 1996
- Effects of Temperature Programming and Pressure on Separation Number and Height Equivalent to a Theoretical Plate in Optimization of a Serially Coupled, Open-Tubular Columns Gas Chromatographic SystemAnalytical Chemistry, 1996
- Separation Window Diagrams for High-Speed GCAnalytical Chemistry, 1995
- Optimization of capillary parameters for gas chromatographyJournal of High Resolution Chromatography, 1984
- Optimization of separation number in gas chromatography with fused silica capillary columns under temperature programmed conditionsAnalytical Chemistry, 1983
- Length‐time and capacity ratio optimization in chromatographyJournal of High Resolution Chromatography, 1983
- Comments on TZ: Its temperature dependence and relationship to other measures of column efficiencyJournal of High Resolution Chromatography, 1980
- Effect of test temperature on separation numberJournal of High Resolution Chromatography, 1980
- Speed of analysis in open tubular column gas chromatographyAnalytical Chemistry, 1978