Pulse oximetry in sickle cell anemia
- 1 September 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 29 (9) , 1803-1806
- https://doi.org/10.1097/00003246-200109000-00025
Abstract
To determine whether pulse oximetry is accurate and if it correlates with arterial blood gas saturation in pediatric patients with sickle cell anemia. Prospective, comparative study using a convenience sample of patients with sickle cell anemia who had simultaneous arterial blood gas sampling and pulse oximetry. Children’s Memorial Hospital, a large tertiary care pediatric hospital in Chicago, IL. Patients selected from the emergency department and the pediatric intensive care unit. Twenty-four consecutive patients with sickle cell anemia who had simultaneous arterial blood gas sampling and pulse oximetry. Twenty-four patients had a total of 70 simultaneous pulse oximeter and blood gas pair samples. Each patient’s initial pulse oximeter/blood gas pair was used in the statistical analysis. Three patients had venous samples and were excluded from comparison, leaving 21 arterial blood gas/pulse oximeter pairs for analysis. The pulse oximeter correlated well with the cooximeter-measured arterial saturation (r 2 = .74). The pulse oximeter significantly underestimated saturation by a mean of −1.6% (95% confidence interval, −0.3 to −3;p = .03). Pulse oximetry correlates well with cooximeter-measured saturation in patients with sickle cell anemia. Pulse oximetry significantly underestimates true arterial saturation, but the bias is clinically insignificant. Pulse oximetry can be used reliably to estimate the arterial oxygen saturation in patients with sickle cell anemia.Keywords
This publication has 18 references indexed in Scilit:
- Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisisThe American Journal of Emergency Medicine, 1996
- Comparison of oxygenation measurements in pediatric patients during sickle cell crisesThe Journal of Pediatrics, 1994
- Pulse oximetry in sickle cell disease.Archives of Disease in Childhood, 1993
- Pulse OximetryChest, 1990
- Pulse OximetryAnesthesiology, 1989
- Relationship of pulse oximetry to arterial oxygen tension in infantsCritical Care Medicine, 1987
- The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2Anesthesiology, 1987
- Pulse oximetry in pediatric intensive care: Comparison with measured saturations and transcutaneous oxygen tensionThe Journal of Pediatrics, 1985
- Comparison of a pulse oximeter with an ear oximeter and an in-vitro oximeterJournal of Clinical Monitoring and Computing, 1985
- Evaluation of Pulse OximetryAnesthesiology, 1983