Evaluation of bioprosthetic valve-associated thrombus in ventricular assist device patients.
- 1 November 1993
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 88 (5) , 2023-2029
- https://doi.org/10.1161/01.cir.88.5.2023
Abstract
BACKGROUND Thromboembolic events may be related to thrombotic deposition on prosthetic valves. In a left ventricular assist device (LVAD) that contains two porcine pericardial bioprosthetic valves in addition to significant associated biomaterial placement, this may be particularly true. Thrombotic deposits on valves removed from LVADs at autopsy or heart transplantation were scored to determine (1) the nature and location of valvular deposition, (2) whether deposition was related to thromboembolic events, (3) correlations between deposition and patient hemodynamic and coagulation parameters, and (4) implant time dependency. METHODS AND RESULTS Novacor LVADs were implanted in 23 patients as a bridge to transplantation for 1 to 303 days. Photographs of the concave (downstream) and convex (upstream) side of the inflow and outflow valve were made at explant and later scored for (1) total thrombus area (10 = equivalent of cusp area), (2) percent of cusp area occupied by solid thrombus, (3) thrombus color (10 = dark red, 0 = white), and (4) average percent of valve strut height involved with thrombus (from a side view). The inflow valve was shown to have heavier and redder deposition than the outflow valve. This was also true for the concave versus the convex side. Heaviest deposition was seen on the inflow valve concave side, which rests within the LVAD pumping sac and may be subject to poor convection. Patients with neurological thromboembolic events (8/23) during implantation had heavier deposition on the inflow valve concave side (5.7 +/- 2.7 versus 4.6 +/- 2.2, P < .05). Pump volumetric output was also found to negatively correlate with thrombus area on this valve and side (r = -.61, P = .002). Platelet release (platelet factor 4) was correlated with thrombus involvement on the upstream (convex) side of the inflow valve (r = .82, P = .002). No significant dependence of deposition on the implant time was found. CONCLUSIONS Valve thrombus deposition was related to thromboembolic events. Pump volumetric output and platelet release were found to be related to deposition. These results may have implications for the role of hemodynamics and platelet activation in thromboembolism associated with prosthetic valve placement in general.Keywords
This publication has 14 references indexed in Scilit:
- Hematological Problems During the Use of Cardiac Assist Devices: Clinical Experiences in JapanArtificial Organs, 2008
- Thrombin Activity Resides on LVAD Dacron Inflow and Outflow GraftsAsaio Journal, 1992
- Optimal Management of a Ventricular Assist System Contribution of Flow Visualization StudiesAsaio Journal, 1992
- Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist deviceThe Annals of Thoracic Surgery, 1992
- Hemostatic Alterations Caused by Ventricular Assist Devices for Postcardiotomy Heart FailureArtificial Organs, 1991
- Quantification of Perivalvular Thrombus Formation in Blood Pumps by Polar Coordinate MappingArtificial Organs, 1990
- Experience with univentricular support in mortally ill cardiac transplant candidatesThe Annals of Thoracic Surgery, 1990
- Thromboembolic Complications of the Symbion AVAD SystemArtificial Organs, 1989
- A Totally Implantable Ventricular Assist Device for End-Stage Heart DiseasePublished by Springer Nature ,1984
- THE BLOOD INTERFACE AT ARTIFICIAL SURFACES WITHIN A LEFT VENTRICULAR ASSIST SYSTEMAnnals of the New York Academy of Sciences, 1983