Predictors of between-method differences in cardiac output measurement using thoracic electrical bioimpedance and thermodilution
- 1 October 1995
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 23 (10) , 1667-1673
- https://doi.org/10.1097/00003246-199510000-00010
Abstract
To evaluate the usefulness of transthoracic electrical bioimpedance in trending changes in cardiac output after cardiac surgery, and to identify predictors of differences between cardiac output measured by thermodilution and transthoracic electrical bioimpedance methods. Prospective repeated-measures study. University-affiliated tertiary care center. Thirty-four adult patients undergoing elective cardiac surgery with routine pulmonary artery catheter placement. Simultaneous paired cardiac output measurements by transthoracic electrical bioimpedance and thermodilution were made at four time points: within 2 hrs of intensive care unit (ICU) admission; when the patient reached a normothermic temperature; after extubation; and 24 hrs after ICU admission. Mean measurements by each method over time did not differ, except at ICU admission, when compared by repeated-measures analysis of variance. For each time point, bias and precision between methods were calculated. Bias calculations ranged from 0.02 to 0.21 L/min/m2. Precision calculations ranged from 1.06 to 1.52 L/min/m2. Predictors of between-method differences identified by a multiple regression model of hemodynamic variables were: increased systemic vascular resistance index, decreased mean arterial pressure (MAP), and the presence of atrial or ventricular pacing. While mean postoperative cardiac output measurements did not differ by method over time, agreement between transthoracic electrical bioimpedance and thermodilution methods was poor in the immediate postoperative period, with precision calculations indicative of clinically significant differences. Increased systemic vascular resistance index and decreased MAP were predictive of larger between-method differences.Keywords
This publication has 15 references indexed in Scilit:
- Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patientsCritical Care Medicine, 1993
- Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinationsThe American Journal of Cardiology, 1992
- Determination of cardiac output during positive endexpiratory pressure—Noninvasive electrical bioimpedance compared with standard thermodilutionCritical Care Medicine, 1990
- Noninvasive Cardiac Output: Simultaneous Comparison of Two Different Methods with ThermodilutionAnesthesiology, 1990
- Comparison of two impedance cardiographic techniques for measuring cardiac output in critically ill patientsCritical Care Medicine, 1989
- Multicomponent noninvasive physiologic monitoring of circulatory functionCritical Care Medicine, 1988
- Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patientsCritical Care Medicine, 1986
- Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedanceCritical Care Medicine, 1986
- First Annual Herbert S. Shubin Memorial LectureCritical Care Medicine, 1977
- Simultaneous determinations of cardiac output by thermal dilution, fiberoptic and dye-dilution methodsThe American Journal of Cardiology, 1970