Effects of non-uniform conductivity fluids in electromagnetic flowmeters
- 1 April 1970
- journal article
- research article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 3 (4) , 637-639
- https://doi.org/10.1088/0022-3727/3/4/328
Abstract
A numerical solution gives the expected change in output signal, when the velocity and conductivity profiles are axisymmetric, for an electromagnetic flowmeter with uniform magnetic field and a first-order variation to that field.Keywords
This publication has 2 references indexed in Scilit:
- Effect of Hematocrit Value upon Electromagnetic Flowmeter SensitivityCirculation Research, 1969
- Solutions of the electromagnetic flowmeter equation for cylindrical geometriesJournal of Physics D: Applied Physics, 1968