Amplification of xuv harmonic radiation in a gallium amplifier
- 1 June 1995
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review A
- Vol. 51 (6) , R4337-R4340
- https://doi.org/10.1103/physreva.51.r4337
Abstract
We report the observation of amplification of an xuv harmonic pulse in an xuv laser. The 21st harmonic of a frequency-doubled 1.3-psec neodymium chirped-pulse-amplification laser pulse was injected into the gain region of an 18-mm-long Ga X X I I x-ray amplifier. A gain of approximately 3 was recorded for the 21st harmonic, relative to the unamplified 19th and 23rd harmonics when the harmonic wavelength was tuned to overlap the 25.11-nm J=2–1 laser transition.Keywords
This publication has 2 references indexed in Scilit:
- Energy-yield and conversion-efficiency measurements of high-order harmonic radiationPhysical Review A, 1995
- Absolute Calibration Of An Xuv Time Resolving SpectrographPublished by SPIE-Intl Soc Optical Eng ,1988