New optical monitoring method for arc-fusion splice of single-mode fibres and high-precision estimation of splice loss
- 28 October 1982
- journal article
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 18 (22) , 972-973
- https://doi.org/10.1049/el:19820667
Abstract
A new local monitoring system with a 1.5 μm LD is proposed, utilising fibre bending just behind the splice. By the use of index-matching fluid completely evaporated by arc-discharge, splice loss and strength of splice point are not degraded, and, furthermore, the splice loss can be estimated with a precision of ± 0.01 dB.Keywords
This publication has 0 references indexed in Scilit: