Rapid repair of titanium particle‐induced osteolysis is dramatically reduced in aged mice
Open Access
- 1 March 2001
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 19 (2) , 171-178
- https://doi.org/10.1016/s0736-0266(00)00033-4
Abstract
Aseptic loosening is the most common cause of orthopaedic implant failure. This process is thought to be due to osteolysis induced by implant‐derived wear particles. Teitelbaum and colleagues have recently developed a promising murine calvarial model of wear particle‐induced osteolysis. However, prior to this study, this model had only been assessed qualitatively. We now report a reproducible, quantitative version of the calvarial model of wear particle‐induced osteolysis, in which the extent of osteolysis (and repair) of entire parietal bones is assessed by histomorphometry of contact microradiographs. Using this model, we found that the osteolytic response is transient and rapidly repaired in one month old mice. The extent of osteolysis peaks 7 days after particle implantation and returns to baseline levels by 13 days. A similar amount of osteolysis and even more extensive repair is observed when particles are implanted repeatedly. In contrast, aged mice develop progressive osteolysis with no detectable repair. As a result, 26 month old mice have approximately 17‐fold more osteolysis than one month old mice 21 days after particle implantation. Skeletally mature, adult mice (4–16 months old) show an intermediate pattern of response. Osteolysis in these mice peaks at 7 days after particle implantation but it is repaired more slowly than in the one month old mice. Taken together, these results underscore the role of an imbalance between bone resorption and bone formation in the development of aseptic loosening and suggest that agents that stimulate bone formation maybe useful in prevention or treatment of aseptic loosening. © 2001 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.Keywords
This publication has 42 references indexed in Scilit:
- Tumor necrosis factor‐α/nuclear transcription factor‐κB signaling in periprosthetic osteolysisJournal of Orthopaedic Research, 2000
- Measurement and removal of adherent endotoxin from titanium particles and implant surfacesJournal of Orthopaedic Research, 1999
- Independent impairment of osteoblast and osteoclast differentiation in klotho mouse exhibiting low-turnover osteopeniaJournal of Clinical Investigation, 1999
- Age-Related Osteogenic Potential of Mesenchymal Stromal Stem Cells from Human Vertebral Bone MarrowJournal of Bone and Mineral Research, 1999
- Migration, Particles, and Fluid PressurePublished by Wolters Kluwer Health ,1998
- Concentration of Transforming Growth Factor Beta in Human Bone Tissue: Relationship to Age, Menopause, Bone Turnover, and Bone VolumeJournal of Bone and Mineral Research, 1998
- Inhibition of Wear Debris Mediated Osteolysis in a Canine Total Hip Arthroplasty ModelPublished by Wolters Kluwer Health ,1997
- Age-related changes in osteogenic stem cells in miceJournal of Bone and Mineral Research, 1996
- Bone formation and bone resorption in failed total joint arthroplasties: Histomorphometric analysis with histochemical and immunohistochemical techniqueJournal of Orthopaedic Research, 1996
- Relations between histologic indices of bone formation: Implications for the pathogenesis of spinal osteoporosisJournal of Bone and Mineral Research, 1995