Volume guarantee: Stability of tidal volume and incidence of hypocarbia
- 16 June 2004
- journal article
- clinical trial
- Published by Wiley in Pediatric Pulmonology
- Vol. 38 (3) , 240-245
- https://doi.org/10.1002/ppul.20063
Abstract
Excessive tidal volume (V(T)) can lead to lung injury, hypocarbia, and neurologic damage. Volume guarantee (VG) uses exhaled V(T) as the control variable to reduce the risk of volutrauma and more closely control PaCO(2). Our objective was to test the hypothesis that VG combined with assist/control (A/C) will maintain PaCO(2) and V(T) within target range more consistently than assist/control alone during the first 72 hr of life in ventilated preterm infants. Eligible infants were randomly assigned to A/C + VG or A/C alone. Data were recorded directly from the pressure and volume module of the Draeger Babylog 8000+ ventilator. Arterial blood gases were obtained every 2-6 hr, as clinically indicated. In A/C, inspiratory pressure was adjusted to achieve a V(T) of 4-6 ml/kg. In VG, the target V(T) was 5 ml/kg. Subsequent adjustments were made by the clinical team in response to arterial blood gas measurements (ABG). Proportion of breaths and PaCO(2) values outside the target range were compared by chi(2), and continuous variables by t-test. There were no differences in demographic or baseline ventilator variables between the 18 infants in the two groups. For 1,805/11,950 breaths (15.1%), V(T) was > target with A/C + VG, vs. 2,503/9,853 (25.4%) with A/C (P < 0.001). V(T) was < target for 21.7% of breaths with A/C + VG, vs. 35.7% with A/C (P < 0.001). Twenty percent of PaCO(2) values were < target, with A/C + VG vs. 36.3% with A/C, P < 0.05. The proportion of PaCO(2) values > target was similar in the two groups. Oxygenation and mean pH were not different. No complications related to mechanical ventilation were observed. In conclusion, VG significantly reduced hypocarbia and excessively large V(T). This suggests the potential to reduce pulmonary and neurologic complications of mechanical ventilation. Larger studies are needed to establish safety and demonstrate such benefits.Keywords
This publication has 25 references indexed in Scilit:
- Patient‐ventilator interactions in new modes of patient‐triggered ventilationPediatric Pulmonology, 2001
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000
- Lung Protective Strategies of Ventilation in the Neonate: What Are They?Pediatrics, 2000
- International randomised controlled trial of patient triggered ventilation in neonatal respiratory distress syndromeArchives of Disease in Childhood: Fetal & Neonatal, 2000
- Randomized multicenter trial comparing synchronized and conventional intermittent mandatory ventilation in neonatesThe Journal of Pediatrics, 1996
- Synchronous intermittent mandatory ventilation modes compared with patient triggered ventilation during weaning.Archives of Disease in Childhood: Fetal & Neonatal, 1995
- Improved oxygenation during synchronized intermittent mandatory ventilation in neonates with respiratory distress syndrome: A randomized, crossover studyThe Journal of Pediatrics, 1995
- Hypocarbia and cystic periventricular leukomalacia in premature infantsArchives of Disease in Childhood: Fetal & Neonatal, 1994
- The Effectiveness of Pressure Support Ventilation for Mechanical Ventilatory Support in ChildrenAnesthesiology, 1993
- Etiological Factors Associated with the Development of Periventricular LeukomalaciaActa Paediatrica, 1987