Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation
- 1 February 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 28 (2) , 402-407
- https://doi.org/10.1097/00003246-200002000-00019
Abstract
We noticed that in some patients after cardiac surgery, when flow triggering was used, cardiogenic oscillation might be autotriggering the ventilatory support. In a prospective study, we evaluated the degree of cardiogenic oscillation and the frequency rate of autotriggering. We suspected that autotriggering caused by cardiogenic oscillation was more common than clinically appreciated. Prospective, nonrandomized, clinical study. Surgical intensive care unit in a national heart institute. A total of 104 adult patients were enrolled after cardiac surgery. During the study period, patients were paralyzed and ventilated with intermittent mandatory ventilation at a rate of 10 breaths/min, pressure support of 10 cm H2O, and flow triggering with a sensitivity of 1 L/min. Because the patients would not be able to breathe spontaneously, we counted pressure-support (PS) breaths as instances of autotriggering. Then, we classified the patients into two groups according to the number of PS breaths: an “AT group” (PS breaths of >5/min) and a “non-AT group” (PS breaths of ≤5/min). If autotriggering occurred, we decreased the sensitivity so autotriggering disappeared (threshold triggering sensitivity). The intensity of cardiogenic oscillation was assessed as the flow and airway pressure at the airway opening. A total of 23 patients (22%) demonstrated more than five autotriggered breaths/min. During mechanical ventilation, the inspiratory flow fluctuation caused by cardiogenic oscillation was significantly greater in the AT group than in the non-AT group (4.67 ± 1.26 L/min vs. 2.03 ± 0.86 L/min; p < .01). The AT group also showed larger cardiac output, higher ventricular filling pressures, larger heart size, and lower respiratory system resistance than the non-AT group. As the inspiratory flow fluctuation caused by cardiogenic oscillation increased, the level of triggering sensitivity also was increased to avoid autotriggering. In the AT group with 1 L/min of sensitivity, the respiratory rate increased (19.9 ± 2.7 vs. 10 ± 0 breaths/min, p < .01), PaCO2 decreased (30.8 ± 4.0 torr [4.11 ± 0.36 kPa] vs. 37.6 ± 4.3 torr [5.01 ± 0.57 kPa]; p < .01), and mean esophageal pressure increased (7.7 ± 3.0 vs. 6.9 ± 3.0 cm H2O; p < .01) compared with the threshold triggering sensitivity. Autotriggering caused by cardiogenic oscillation is common in postcardiac surgery patients when flow triggering is used. Autotriggering occurred more often in patients with more dynamic circulation. Autotriggering caused respiratory alkalosis and hyperinflation of the lungs.Keywords
This publication has 13 references indexed in Scilit:
- Pressure vs Flow Triggering During Pressure Support VentilationChest, 1997
- Patient-triggered ventilation in neonates: comparison of a flow-and an impedance-triggered system.American Journal of Respiratory and Critical Care Medicine, 1996
- Patient-triggered ventilation: A comparison of tidal volume and chestwall and abdominal motion as trigger signalsPediatric Pulmonology, 1996
- Severe hyperventilation and respiratory alkalosis during pressure‐support ventilation: report of a hazardAnaesthesia, 1995
- Airway leak size in neonates and autocycling of three flow-triggered ventilatorsCritical Care Medicine, 1995
- Patient-ventilator interaction during synchronized intermittent mandatory ventilation. Effects of flow triggering.American Journal of Respiratory and Critical Care Medicine, 1995
- Influence of pressure- and flow-triggered synchronous intermittent mandatory ventilation on inspiratory muscle workCritical Care Medicine, 1994
- Comparison of Pressure and Flow Triggering Systems During Continuous Positive Airway PressureChest, 1994
- Comparison of inspiratory work of breathing between flow-triggered and pressure-triggered demand flow systems in rabbitsCritical Care Medicine, 1994
- Inspiratory work of breathing on flow-by and demand-flow continuous positive airway pressureCritical Care Medicine, 1989