Bone cement not weakened by cefuzonam powder
- 1 January 1991
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 62 (3) , 232-237
- https://doi.org/10.3109/17453679108993599
Abstract
We report tensile, shearing, and bending tests on bone cement to which cefuzonam sodium (Cosmosin®), a third generation cephalosporin, had been mixed. Mixing 3 g of cefuzonam sodium to 40 g of polymethyl methacrylate (PMMA) polymer did not diminish the strength of the bone cement in any of the tests. We speculated that this lack of influence was because the cefuzonam sodium powder used was in the form of relatively uniform-sized spheres and therefore did not become the origin of stress concentration within the cement.Keywords
This publication has 4 references indexed in Scilit:
- Effects of preparation techniques on the porosity of acrylic cementsActa Orthopaedica, 1988
- Mechanical versus manual mixing of bone cementActa Orthopaedica, 1988
- Vacuum mixing of acrylic bone cementThe Journal of Arthroplasty, 1987
- Bone cement improved by vacuum mixing and chillingActa Orthopaedica, 1987