Influence of catheter position on estimated strain in intravascular elastography
- 1 May 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 46 (3) , 616-625
- https://doi.org/10.1109/58.764848
Abstract
In elastography, an erroneous strain estimate is obtained when the radial strain and the probing ultrasound beam are not properly aligned: the "strain projection artifact". In practice, an angle between the strain and the ultrasound beam will be present in most of the cases due to inhomogeneities or nonuniform compression. In this study, a theoretical function describing the strain projection artifact is derived as a function of the angle between the radial strain and the ultrasound beam. Two main factors for an angle between strain and ultrasound beam in intravascular elastographic experiments are eccentricity and tilt of the transducer. The theoretical functions describing these errors are corroborated with strain estimates from an experiment with a circular, homogeneous gel-based vessel phantom. Comparison between the theoretical functions and the experimental results reveals that the strain projection artifact is well described by the theoretical findings. As a result, the experimental data can be corrected for this artifact. The corrected elastograms reveal that correct strain estimates are obtained when the eccentricity of the intravascular catheter is less than 63%. An "off-the-wall" device may be required to advance intravascular elastography to in vivo implementation.Keywords
This publication has 31 references indexed in Scilit:
- Reduction of stress nonuniformities by apodization of compressor displacement in elastographyUltrasound in Medicine & Biology, 1996
- Deformation models and correlation analysis in elastographyThe Journal of the Acoustical Society of America, 1996
- Lateral displacement estimation using tissue incompressibilityIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1996
- Internal displacement and strain imaging using ultrasonic speckle trackingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1994
- Distribution of circumferential stress in ruptured and stable atherosclerotic lesions. A structural analysis with histopathological correlation.Circulation, 1993
- Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast In VivoUltrasonic Imaging, 1993
- Computational structural analysis based on intravascular ultrasound imaging before in vitro angioplasty: Prediction of plaque fracture locationsJournal of the American College of Cardiology, 1993
- Axial stress distributions between coaxial compressors in elastography: An analytical modelUltrasound in Medicine & Biology, 1992
- Geometric Accuracy of Intravascular Ultrasound ImagingJournal of the American Society of Echocardiography, 1992
- Elastography: A quantitative method for imaging the elasticity of biological tissuesUltrasonic Imaging, 1991