Broadband six-port reflectometer junction
- 27 October 1983
- journal article
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 19 (22) , 921-922
- https://doi.org/10.1049/el:19830629
Abstract
The letter describes a six-port junction for use in a reflectometer having a theoretical bandwidth equal to that of its four constituent directional couplers. Their voltage coupling coefficients can be chosen to optimise the resolution in measuring voltage reflection coefficient Γ, given the same fullscale indication for each of the four detectors. Experiment indicates that, using thermistor detectors, a standard deviation of less than 5×10−4 in |Γ| can be achieved with less than 1 mW power incident on this junction.Keywords
This publication has 0 references indexed in Scilit: