Design and Construction of Glutamine Binding Proteins with a Self-Adhering Capability to Unmodified Hydrophobic Surfaces as Reagentless Fluorescence Sensing Devices
- 1 December 2003
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 125 (52) , 16228-16234
- https://doi.org/10.1021/ja036459l
Abstract
The chemically and genetically remodeling of proteins with ligand binding specificities can be utilized to synthesize various protein-based microsensors for detecting single biomolecules. Here, we describe the construction and characterization of fluorophore-labeled glutamine binding proteins (QBP) and derivatives coupled to the independently designed hydrophobic polypeptide (E12) that can adhere onto solid surfaces via hydrophobic interactions. The single cysteine mutant (N160C QBP) modified with the three environmentally sensitive fluorescent dyes (IAANS, acrylodan, and IANBD ester) showed increased changes in fluorescence intensity induced by glutamine binding. The use of these conjugates as reagentless fluorescence sensors enables us to determine the glutamine concentrations (0.1-50 microM) in homogeneous solution. The fusion of N160C QBP with E12, (Gly4-Ser)n spacers (GSn), and IANBD resulted in the novel fluorescence sensing elements having an adhering capability to hydrophobic surfaces of unmodified microplates. In ELISA and fluorescence experiments for the microplates treated with a series of the conjugates, IANBD-labeled N160C QBP-GS1-E12 displayed the best reproducibility in adhesion onto the hydrophobic surfaces and the precise correlation between fluorescence changes and glutamine concentrations. The performance of the biosensor-attached microplate for glutamine titrations demonstrated that the hydrophobic interaction of E12 with solid surfaces is useful for effective immobilization of proteins that need specific conformational movements in recognizing particular biomolecules. Therefore, the technique using E12 as a surface-linking domain for protein adhesion onto unmodified substrates could be applied effectively to prepare microplates/arrays for a wide variety of high-throughput assays on chemical and biological samples.Keywords
This publication has 21 references indexed in Scilit:
- Design of Bioelectronic Interfaces by Exploiting Hinge-Bending Motions in ProteinsScience, 2001
- Protein Purification by Fusion with an Environmentally Responsive Elastin-Like Polypeptide: Effect of Polypeptide Length on the Purification of ThioredoxinBiotechnology Progress, 2001
- By-passing selection: direct screening for antibody-antigen interactions using protein arraysNucleic Acids Research, 2000
- Engineering Biosensors by Introducing Fluorescent Allosteric Signal Transducers: Construction of a Novel Glucose SensorJournal of the American Chemical Society, 1998
- Desperately seeking sensorsChemistry & Biology, 1995
- Engineering the Maltose Binding Protein for Reagentless Fluorescence SensingAnalytical Chemistry, 1994
- Biosensors — what real progress is being made?Trends in Biotechnology, 1993
- Two Cytosolic Neutrophil Oxidase Components Absent in Autosomal Chronic Granulomatous DiseaseScience, 1988
- Interaction of deoxyribonucleic acid with histone f2b and its half-molecules. Circular dichroism studiesBiochemistry, 1974
- Radio Detection of Interstellar CHNature, 1973