Reproducibility of transvaginal three-dimensional endometrial volume measurements during ovarian stimulation
- 1 October 1999
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in Human Reproduction
- Vol. 14 (10) , 2604-2608
- https://doi.org/10.1093/humrep/14.10.2604
Abstract
Before estimating the clinical role of a method, the reproducibility has to be evaluated precisely. This study aimed to document the reproducibility of the endometrial volume measurement by three-dimensional (3D)-ultrasound. The volume measurements were done on 57 consecutive in-vitro fertilization (IVF) patients with either the full planar (contour) or the three distance method. A paired t-test provided no statistically significant difference between the two methods. Linear regression analysis, using the full planar method as independent and the other as dependent variables, yielded the following results: intercept = 0.348, not statistically different from 0; slope = 0.962, statistically different from 1 (P < 0.01). Interobserver reliability for the three distance method was 0.6667 and for the full planar method was 0.9565. Intra-observer reliability for the three distance method was 0.8426 and for the full planar method 0.9394. The correspondence between and within observers seemed to be good. Both methods are reliable, but the full planar method seems to provide slightly better reproducibility in regard to endometrium volume measurement.Keywords
This publication has 13 references indexed in Scilit:
- Endometrial oestrogen and progesterone receptors and their relationship to sonographic appearance of the endometriumHuman Reproduction Update, 1998
- Endometrial volume change during spontaneous menstrual cycles: volumetry by transvaginal three-dimensional ultrasoundFertility and Sterility, 1997
- Endometrial ultrasonography as a predictor of pregnancy in an in-vitro fertilization programme after ovarian stimulation and gonadotrophin-releasing hormone and gonadotrophinsHuman Reproduction, 1997
- Endometrial thickness and serum oestradiol concentrations as predictors of outcome in oocyte donationHuman Reproduction, 1997
- Transvaginal three-dimensional ultrasound: reproducibility of ovarian and endometrial volume measurementsFertility and Sterility, 1996
- The diagnostic value of endometrial thickness and volume measurements by three‐dimensional ultrasound in patients with postmenopausal bleedingUltrasound in Obstetrics & Gynecology, 1996
- Three‐dimensional ultrasound: accuracy of distance and volume measurementsUltrasound in Obstetrics & Gynecology, 1996
- Clinical application of volume estimation based on three‐dimensional ultrasonographyUltrasound in Obstetrics & Gynecology, 1995
- 177 Accuracy of 3-D Sonographic Volume MeasurementsAmerican Journal of Obstetrics and Gynecology, 1993
- Sonography of the endometrium during conception and nonconception cycles of in vitro fertilization and embryo transferFertility and Sterility, 1986