PreLoad-responsive, Pulsatile-Flow, Externally Valved Pump: Cardiopulmonary Bypass
- 1 January 1989
- journal article
- research article
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 2 (3) , 269-279
- https://doi.org/10.3109/08941938909057433
Abstract
Currently two pumps are used for cardiopulmonary bypass, the roller pump and the centrifugal or vortex pump. Both are steady-flow pumps. The procedure of cardiopulmonary bypass possesses a finite morbidity and mortality. The degree to which steady flow is responsible for this morbidity and mortality remains to be clarified, but investigators have established the fact that a physiologic degree of pulsatile flow must be achieved before its beneficial results, such as normal systemic resistance and absence of lactate production, can be demonstrated. Availability of a satisfactory pulsatile pump for cardiopulmonary bypass has been a problem in the past but the pump presented here may satisfy this need. It produces physiologic pulsatility with rate dependent ejection time equal to or less than that of humans (413 microseconds minus 1.7 times heart rate), and it is preload-responsive, varying its pumping rate and output with filling pressure. The pump is externally valved to minimize hemolysis, which has been demonstrated in two laboratory studies to be significantly less than with the roller pump. It produces pulsatile flow through membrane oxygenators. The pump is thought to have potential for several clinical applications in addition to (1) pulsatile-flow cardiopulmonary bypass, including (2) left, right, or combined transthoracic QRS synchronized ventricular assist, (3) femoral vein to femoral artery QRS synchronized left ventricular assist, (4) adult or infant ECMO, (5) pulsatile flow hemodialysis. In the latter, spallation and embolization of hemodialysis tubing particles should not be a problem as has proved to be the case with the present hemodialysis pump.Keywords
This publication has 15 references indexed in Scilit:
- Analysis of microembolic particles originating in extracorporeal circuitsPerfusion, 1987
- Reduction of blood trauma in roller pumps for long‐term perfusionWorld Journal of Surgery, 1985
- Peripheral vascular resistance and angiotensin II levels during pulsatile and no-pulsatile cardiopulmonary bypass.Thorax, 1979
- Systemic hypertension following myocardial revascularizationAmerican Heart Journal, 1973
- Brain damage and mortality in dogs following pulsatile and non-pulsatile blood flows in extracorporeal circulationThorax, 1972
- Bioengineering efforts in developing artificial hearts and assistorsThe American Journal of Surgery, 1967
- History of the Pump OxygenatorArchives of Surgery, 1966
- Pulsatile and Nonpulsatile Blood FlowJAMA, 1965
- Mechanical Heart--Lung for Use in ManBMJ, 1953
- Apparat zur Durchblutung isolirter überlebender OrganeNaunyn-Schmiedebergs Archiv für experimentelle Pathologie und Pharmakologie, 1890