Capillary electrophoresis/mass spectrometry determination of inorganic ions using an ion spray‐sheath flow interface
- 1 January 1993
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 14 (1) , 531-539
- https://doi.org/10.1002/elps.1150140181
Abstract
The determination of inorganic cations and anions by capillary electrophoresis/mass spectrometry (CE/MS) is reported using an ion spray-sheath flow interface coupling. A twelve-component synthetic mixture of cations which included the positive ions of K, Ba, Ca, Mn, Cd, Co, Pb, Cr, Ni, Zn, Ag, and Cu was loaded into the capillary column at levels ranging from 30 to 300 pg, separated by CE, and detected by indirect UV and in the full-scan (m/z 35–450) positive ion CE/MS mode using an aqueous buffer containing 30 mM creatinine and 8 mM α-hydroxyisobutyric acid, pH 4.8. Creatinine forms adducts with the cations which are observed in the gas phase and requires rather high (120 electron volts) declustering energy to dissociate. This produces a reduction in charge state to form the free, singly charged, inorganic cations which are observed in the mass spectra. CE/MS analysis of an aqueous acidic extract of used aircraft engine oil revealed high levels of lead as well as lower levels of chromium and nickel. CE-indirect UV analysis of a synthetic mixture containing 300 pg each of 11 inorganic ions, which included the anions of Br, Cl, NO2, NO3, S2O3, N3, SCN, SO4, SeO4, oxalate, and MoO4, is shown. The running buffer which affected this separation contained 5 mM ammonium dichromate, 10 mM ammonium acetate, and 20 mM diethylenetriamine at pH 9.3. Although indirect UV detection revealed good separation of these anions, CE/MS analysis of this mixture was complicated by interfering ion current signals from the cluster ions formed by the interaction between the additives and the analytes. Thus only three of these singly charged anions, e.g. Br, SCN, and HSeO4, could be satisfactorily detected in this mixture by CE/MS.Keywords
This publication has 35 references indexed in Scilit:
- Controlled changes of selectivity in the separation of ions by capillary electrophoresisJournal of Chromatography A, 1991
- INDIRECT DETECTION METHODS FOR CAPILLARY SEPARATIONSAnalytical Chemistry, 1991
- Capillary electrophoresisAnalytical Chemistry, 1990
- Capillary zone electrophoresis of rare earth metals with indirect UV absorbance detectionElectrophoresis, 1990
- Indirect photometric detection in capillary zone electrophoresisJournal of Chromatography A, 1989
- High-performance capillary electrophoresis in the biological sciencesJournal of Chromatography B: Biomedical Sciences and Applications, 1989
- Effect of electrolyte and sample concentraton on the relatioship between sensitivity and resolution in capillary zone electrophoresis using conductivity detectionJournal of Chromatography A, 1989
- Optimization of sensitivity and separation in capillary zone electrophoresis with indirect fluorescence detectionAnalytical Chemistry, 1988
- On-line mass spectrometric detection for capillary zone electrophoresisAnalytical Chemistry, 1987
- Free zone electrophoresisChromatographic Reviews, 1967