Ultra Low Dose CT Attenuation Correction Maps for Emission Computed Tomography
- 1 January 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (10823654) , 2123-2127
- https://doi.org/10.1109/nssmic.2006.354333
Abstract
We present a method for obtaining attenuation maps for use in emission computed tomography (ECT) using ultra low dose CT data (at 140kVp, down to 10mA). This is achieved using a recursive k-means clustering method, the output of which initializes successive parameter-less region growing procedures. The method automatically produces templates corresponding to bone, lung, soft and dense tissue (muscle and fat). The segmentation of each tissue class from k-means clustering is used to compensate for the higher statistical noise variation seen at lower dose. The use of the region grower provides local contextual information that minimizes the impact of global noise. The templates were assigned appropriate linear attenuation coefficients and then convolved with the PET/SPECT system's PSF. This approach was applied to a dataset from an experimental anthropomorphic phantom exposed to systematically reducing CT dose derived from an X-ray beam at 140kVp and varying current from 160mA (full diagnostic dose) to 10mA (ultra low dose). Preliminary results show that for the purpose of CT attenuation correction, it is possible to successfully produce attenuation maps at ultra low dose with very low error (compared to full diagnostic dose) if used with the segmentation method presented.Keywords
This publication has 8 references indexed in Scilit:
- The use of X-ray CT for attenuation correction of PET dataPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficientsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- Fuzzy clustering-based segmented attenuation correction in whole-body PET imagingPhysics in Medicine & Biology, 2002
- An automatic classification technique for attenuation correction in positron emission tomographyEuropean Journal of Nuclear Medicine and Molecular Imaging, 1999
- Attenuation correction for a combined 3D PET/CT scannerMedical Physics, 1998
- Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessmentIEEE Transactions on Nuclear Science, 1996
- Adaptive, segmented attenuation correction for whole-body PET imagingIEEE Transactions on Nuclear Science, 1996
- Investigation of the use of X-ray CT images for attenuation compensation in SPECTIEEE Transactions on Nuclear Science, 1994