Development of a HeCd Laser-Based Fluorescence Detector for Analysis of Derivatized Biogenic Amines
- 1 October 1992
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 46 (10) , 1532-1539
- https://doi.org/10.1366/000370292789619250
Abstract
The development of a highly sensitive laser-induced fluorescence (LIF) detector for HPLC is described. It was specifically designed to monitor the fluorescence emitted from biogenic amines which were derivatized by naphthalenedicarboxaldehyde (NDA) in the presence of cyanide ion. The product of the amine derivatization, cyanobenz[f]isoindole (CBI), absorbs radiation at the output wavelength of the HeCd laser (441.6 nm). Optimization of detector sensitivity included evaluation of both optical components and cell configurations. A laser dye, coumarin 7, served as the test analyte because its native spectral properties coincided with those of the CBI-amine adducts and because no derivatization step was required for each injection. A limit of detection (LOD) on the order of 2 × 10−12 M was reproducibly observed.Keywords
This publication has 16 references indexed in Scilit:
- High Sensitivity Fluorescence Detection of Naphthalenedialdehyde-Derivatized Amino Acids with a Low Power Helium-Cadmium Laser for High Performance Liquid Chromatographic AnalysisAnalytical Sciences, 1989
- Naphthalene-2,3-dicarboxyaldehyde/cyanide ion: a rationally designed fluorogenic reagent for primary aminesAnalytical Chemistry, 1987
- N-substituted 1-cyanobenz[f]isoindole: evaluation of fluorescence efficiencies of a new fluorogenic label for primary amines and amino acidsAnalytical Chemistry, 1987
- PERKIN-ELMERAnalytical Chemistry, 1987
- New derivatizing agents for amino acids and peptides. 1. Facile synthesis of N-substituted 1-cyanobenz[f]isoindoles and their spectroscopic propertiesThe Journal of Organic Chemistry, 1986
- Optimization of flow cells for fluorescence detection in liquid chromatographyAnalytical Chemistry, 1982
- Laser-induced fluorescence detection for conventional and microcolumn liquid chromatographyAnalytical Chemistry, 1982
- Determination of adriamycin and daunorubicin in urine by high-performance liquid chromatography with laser fluorometric detectionJournal of Chromatography A, 1980
- CW laser fluorometry using an optical fiber - An application to high performance liquid chromatography.CHEMICAL & PHARMACEUTICAL BULLETIN, 1980
- Laser Fluorimetry: Subpicogram Detection of Aflatoxins Using High-Pressure Liquid ChromatographyScience, 1977