Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
Open Access
- 1 October 2004
- journal article
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 128 (10) , 1151-1156
- https://doi.org/10.5858/2004-128-1151-shaooo
Abstract
Contrast-enhanced magnetic resonance imaging has become a routine diagnostic imaging procedure. Reports in the literature document that 2 of the 4 available gadolinium-based magnetic resonance imaging contrast agents, gadodiamide (Omniscan) and gadoversetamide (OptiMARK), are less stable and readily undergo dechelation. In vitro, this dechelation can result in interference with the most common laboratory methods used to measure total plasma or serum calcium. The result of total calcium measurement soon after contrast-enhanced magnetic resonance imaging with these interfering contrast agents is a spurious lowering of the total calcium level. This low calcium measurement may result in a value consistent with hypocalcemia and can persist in patients with renal insufficiency and in patients receiving higher doses of contrast agent. Alternatively, a clinically significant elevated calcium level may be overlooked because of the artificially lowered value. Two of the available gadolinium-based contrast agents, gadoteridol (ProHance) and gadopentetate dimeglumine (Magnevist), have not been to shown to interfere with total calcium measurement. A clinical practice algorithm for the laboratorian, the radiologist, and the clinician is presented to minimize the occurrence and consequences of a spuriously lowered total calcium level due to Omniscan- or OptiMARK-enhanced magnetic resonance imaging.Keywords
This publication has 11 references indexed in Scilit:
- Model for Predicting the Impact of Gadolinium on Plasma Calcium Measured by the o-Cresolphthalein MethodClinical Chemistry, 2004
- Gadolinium Magnetic Resonance Contrast Agents Produce Analytic Interference in Multiple Serum AssaysAmerican Journal of Clinical Pathology, 2004
- Pseudohypocalcemia after magnetic resonance imaging with gadolinium in patients with cirrhosisLiver Transplantation, 2004
- Severe Pseudohypocalcemia after Gadolinium-Enhanced Magnetic Resonance AngiographyNew England Journal of Medicine, 2003
- Gadodiamide Administration Causes Spurious HypocalcemiaRadiology, 2003
- Safety of Magnetic Resonance Contrast MediaTopics in Magnetic Resonance Imaging, 2001
- Interference of magnetic resonance imaging contrast agents with the serum calcium measurement technique using colorimetric reagentsJournal of Pharmaceutical and Biomedical Analysis, 1999
- Human In Vivo Comparative Study of Zinc and Copper Transmetallation After Administration of Magnetic Resonance Imaging Contrast AgentsInvestigative Radiology, 1996
- Reaction of gadolinium chelates with endogenously available ionsMagnetic Resonance Imaging, 1991
- Monitoring of Ionized Calcium during Human Hepatic Transplantation: Critical Values and Their Relevance to Cardiac and Hemodynamic ManagementAmerican Journal of Clinical Pathology, 1986