The Effects of Air and Helium on the Performance of the Ion Trap Detector When Used for Real-Time Monitoring of Some Atmospheric Pollutants
- 1 October 1993
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 4 (10) , 774-781
- https://doi.org/10.1016/1044-0305(93)80034-v
Abstract
The feasibility of using an ion trap detector for real-time monitoring of volatile organic compounds in atmospheric samples is demonstrated. Detection limits in the low part-per-million to low part-per-billion ranges are achieved with an operating dynamic range of at least 5 orders of magnitude. Sample introduction through semipermeable membranes and molecular leak valves was evaluated. The membrane introduction method provided detection limit enhancements of 10–300 times over the molecular leak method. The effects of partial pressure from air and helium buffer gas were studied, and it was determined that, for optimum amounts of air, the helium buffer gas had no apparent effect on sensitivity or resolution. Air acts as the buffer gas to enhance ion signals by collisionally damping ion motion. The enhancement of molecular ion abundance at high partial pressures of air is postulated to be due to charge exchange and possibly collisional stabilization reactions.Keywords
This publication has 27 references indexed in Scilit:
- Membrane Introduction Mass Spectrometry in Environmental AnalysisPublished by American Chemical Society (ACS) ,1992
- A transportable turnkey gas chromatograph—ion trap detector for field analysis of environmental samplesInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Process analytical chemistry. An industrial perspectiveAnalytical Chemistry, 1990
- Mass-selection of reactant ions for chemical ionization in quadrupole ion trap and triple quadrupole mass spectrometersInternational Journal of Mass Spectrometry and Ion Processes, 1989
- Cleaning up sites with on-site process plants. Part 4Environmental Science & Technology, 1989
- Distribution of volatile organic chemicals in outdoor and indoor air: a national VOCs data baseEnvironmental Science & Technology, 1988
- Urban ozone and its precursorsEnvironmental Science & Technology, 1987
- Continuous monitoring device for the collection of 23 volatile organic priority pollutantsAnalytical Chemistry, 1986
- Recent improvements in and analytical applications of advanced ion trap technologyInternational Journal of Mass Spectrometry and Ion Processes, 1984
- Transmission of organic molecules by a silicone membrane gas chromatograph/mass spectrometer interfaceAnalytical Chemistry, 1983