Diagnostic Accuracy of a New Software for Complex Fractionated Electrograms Identification in Patients with Persistent and Permanent Atrial Fibrillation
- 20 September 2008
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (10) , 1024-1030
- https://doi.org/10.1111/j.1540-8167.2008.01219.x
Abstract
Introduction: The elimination of complex fractionated atrial electrograms (CFAEs) has been proposed as a potential target for guiding successful AF substrate ablation. The possibility to efficiently map the atria and rapidly identify CFAEs sites is necessary, before the CFAEs ablation becomes a routine approach. The aims of this study, conducted in patients with persistent and permanent atrial fibrillation (AF), were to analyze by CARTO mapping in the right (RA) and in the left atrium (LA) during AF: (1) the diagnostic accuracy of a new software for CFAEs analysis, (2) the spatial distribution of CFAEs, (3) the regional beat to beat AF intervals (FF). Methods and Results: Twenty-five consecutive patients (four women, 58.8 ± 11.4 years) undergoing radiofrequency catheter ablation for persistent and permanent AF were enrolled in the study. The CFAE software showed a high sensitivity (90%) and specificity (91%) in the identification of CFAEs, using a specific setting of parameters. The LA had a significantly higher prevalence of CFAEs as compared with the RA (30.5% vs 20.3%, P = 0.016). The CFAEs were mostly present in the septum and in the area of coronary sinus ostium (CS os). The FF intervals were significantly shorter in the LA than in the RA (P < 0.01). Conclusion: CARTO system has a high diagnostic accuracy in the identification of CFAEs. Atrial electrical activity (CFAEs, mean FF intervals) during AF showed a significant spatial inhomogeneity.Keywords
This publication has 31 references indexed in Scilit:
- Prospective Study of Atrial Fibrillation Termination During Ablation Guided by Automated Detection of Fractionated ElectrogramsJournal of Cardiovascular Electrophysiology, 2008
- Automated detection and characterization of complex fractionated atrial electrograms in human left atrium during atrial fibrillationHeart Rhythm, 2007
- Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex ElectrogramsCirculation, 2007
- Left Atrial Ablation Versus Biatrial Ablation for Persistent and Permanent Atrial FibrillationJournal of the American College of Cardiology, 2006
- Mechanisms of Wave Fractionation at Boundaries of High-Frequency Excitation in the Posterior Left Atrium of the Isolated Sheep Heart During Atrial FibrillationCirculation, 2006
- High-density activation mapping of fractionated electrograms in the atria of patients with paroxysmal atrial fibrillationPublished by Elsevier ,2005
- Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in HumansCirculation, 2005
- Presence of Left-to-Right Atrial Frequency Gradient in Paroxysmal but Not Persistent Atrial Fibrillation in HumansCirculation, 2004
- Further evidence of localized posterior interatrial conduction delay in lone paroxysmal atrial fibrillationEP Europace, 2001
- Regional Disparities of Endocardial Atrial Activation in Paroxysmal Atrial FibrillationPacing and Clinical Electrophysiology, 1996