Creep-fatigue as a Possible Cause of Dental Amalgam Margin Failure
- 1 March 1985
- journal article
- research article
- Published by SAGE Publications in Journal of Dental Research
- Vol. 64 (3) , 470-475
- https://doi.org/10.1177/00220345850640031701
Abstract
Fracture of the margins is the most common cause of failure of dental amalgam restorations. Both corrosion and creep have been identified as possible contributors to this type of failure. The stresses that induce creep may arise from the continued setting expansion of the amalgam, the formation of corrosion products, mastication, or from the thermal expansion of the amalgam during ingestion of hot foods. The latter two are low-frequency cyclic stresses. The amalgams used in dentistry have fusion temperatures only about 40°C above mouth temperature, and they experience grain boundary sliding during creep deformation. Since grain boundary sliding, low-frequency cyclic stresses, and a temperature near the fusion temperature of the alloy are prerequisites for so-called "creep-fatigue fracture", this type of fracture may contribute to amalgam margin failure. Amalgam made from seven different alloys was condensed into stainless steel dies. After being allowed to set for seven days, the specimens were thermally cycled between 4°C and 50°C for 500 and 1000 cycles. Amalgam margin integrity was evaluated by scanning electron microscopy both before and after each cycling period. The amount of margin fracture was calculated after 1000 cycles. Thermal cycling of amalgam restorations placed in stainless steel dies resulted in predominantly intergranular fracturing of the amalgam margins, indicating that creep-fatigue failure may be a significant contributor to in vivo margin fracturing.Keywords
This publication has 21 references indexed in Scilit:
- Physical metallurgy of dental amalgams. 3. Transverse strength and fracture behaviour during settingJournal of Dentistry, 1983
- Marginal fracture not a predictor of longevity for two dental amalgam alloys: A ten-year studyThe Journal of Prosthetic Dentistry, 1983
- On Creep Mechanisms in AmalgamsJournal of Dental Research, 1983
- Marginal fracture of amalgam restorations. A reviewAustralian Dental Journal, 1981
- Transmission electron metallography of non-γ2 silver dental amalgamsScripta Metallurgica, 1979
- Marginal Failure of Amalgam Class II RestorationJournal of Dental Research, 1977
- Mechanisms of High-Temperature FatiguePublished by ASTM International ,1973
- Fatigue at High TemperaturePublished by ASTM International ,1973
- Clinical evaluation of corrosion resistance of conventional alloy, spherical-particle alloy, and dispersion-phase alloyThe Journal of Prosthetic Dentistry, 1971
- Brittle Fracture of Dental AmalgamJournal of Dental Research, 1965