ECG-gated versus nongated three-dimensional intracoronary ultrasound analysis: Implications for volumetric measurements
- 1 March 1998
- journal article
- clinical trial
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 43 (3) , 254-260
- https://doi.org/10.1002/(sici)1097-0304(199803)43:3<254::aid-ccd3>3.0.co;2-8
Abstract
The quantitative analysis of a three‐dimensional (3‐D) intracoronary ultrasound (ICUS) image data set permits a more comprehensive assessment of coronary arterial segments. The 3‐D image sets are generally acquired during continuous motorized pullbacks. However, the cyclic changes of vascular dimensions and the cyclic spatial displacement of the ICUS transducer relative to the vessel wall can result in characteristic image artifacts, which may limit the applicability of quantitative automated analysis systems. This limitation may be overcome by an ECG‐gated image acquisition. In the present study we acquired in vivo (1) nongated and (2) ECG‐gated 3‐D ICUS image sets of 15 human atherosclerotic coronary arteries and performed a computer‐assisted contour detection of the lumen and total vessel boundaries. Total vessel and lumen volumes measured significantly larger in the nongated versus ECG‐gated end‐diastolic image sets (753 ± 307 mm3 vs. 705 ± 305 mm3; 411 ± 154 mm3 vs. 388 ± 165 mm3, both: P < 0.05). Both end‐diastolic and systolic measurements were available in nine arteries, showing a larger total vessel and lumen volume at systole (664 ± 221 mm3 vs. 686 ± 227 mm3, P = 0.03; 384 ± 164 mm3 vs. 393 ± 170 mm3, P = 0.08). The differences observed may be of particular interest for volumetric ICUS studies, addressing presumably small differences in vessel or lumen dimensions. Cathet. Cardiovasc. Diagn. 43:254–260, 1998.Keywords
This publication has 22 references indexed in Scilit:
- Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaqueAmerican Heart Journal, 1996
- Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: On-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidanceAmerican Heart Journal, 1996
- Value of intracoronary ultrasound and Doppler in the differentiation of angiographically normal coronary arteries: a prospective study in patients with angina pectorisEuropean Heart Journal, 1996
- Small stent size and intimal hyperplasia contribute to restenosis: A volumetric intravascular ultrasound analysisJournal of the American College of Cardiology, 1995
- Atherosclerosis in angiographically “normal” coronary artery reference segments: An intravascular ultrasound study with clinical correlationsJournal of the American College of Cardiology, 1995
- Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions.Circulation, 1994
- Three‐dimensional intravascular ultrasonography: Reconstruction of endovascular stents in vitro and in vivoJournal of Clinical Ultrasound, 1993
- In vitro validation of three-dimensional intravascular ultrasound for the evaluation of arterial injury after balloon angioplastyJournal of the American College of Cardiology, 1992
- Intravascular ultrasound imaging of coronary arteries. Is three layers the norm?Circulation, 1992
- Three-dimensional reconstruction of human coronary and peripheral arteries from images recorded during two-dimensional intravascular ultrasound examination.Circulation, 1991