A histomorphometric comparison of the muscular tissue reactions to high‐density polyethylene in rats and rabbits
- 1 October 1989
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 23 (10) , 1169-1182
- https://doi.org/10.1002/jbm.820231006
Abstract
In order to bring quantitative elements into the rational selection of animal species for the evaluation of in vivo compatibility of biomaterials, a comparison between the muscular tissue response of rats and rabbits was made using quantitative histomorphometry. The experimental model was based on the quantification of the tissue reaction to specimens made of ultra‐high‐density‐polyethylene (UHDPE) implanted in the paravertebral muscles, according to ASTM F‐469 standard. The tissue reaction was evaluated by digitization of both the encapsulating membrane contours and the different cells types located within it. In each animal species, the cell distribution from the interface exhibited an asymetric bell‐shape curve with a maximum close to the interface, corresponding to a three‐parameter statistical model. The membrane thikness, a fibrocyte‐related parameter, was larger in the rabbit, but its time‐course was identical in each species, showing a late and significant increase. Few differences were observed for most cell types due to the low level of foreign‐body‐reaction induced by HDPE implants. Although there were interspecies differences for fibrocytes and, to a lesser extent, macrophages, between 2 and 8 weeks, weeks, there was no statistical differences for any of the computed parameters either at 2 weeks or between 26‐week rats and 52‐week rabbits. The quantitative histomorphometry picked up differences between close tissue responses, whereas the qualitative observation was unable to demonstrate distinguishing differences between rats and rabbits.This publication has 8 references indexed in Scilit:
- Tissue reaction to ceramic implant materialJournal of Biomedical Materials Research, 1979
- A wear resistant material for total joint replacement?tissue biocompatibility of an ultra-high molecular weight (UHMW) polyethylene?graphite compositeJournal of Biomedical Materials Research, 1974
- The foreign body reaction—an experimental protocolJournal of Biomedical Materials Research, 1974
- Local reaction to polyurethane?a comparative study in the mouse, rat, and rabbitJournal of Biomedical Materials Research, 1973
- Subacute toxicity testing of biomaterials using histopathologic evaluation of rabbit muscle tissueJournal of Biomedical Materials Research, 1973
- The significance of implant shape in experimental testing of biological materials: Disc vs. RodJournal of Biomedical Materials Research, 1970
- Tissue reaction in rabbit muscle exposed to metallic implantsJournal of Biomedical Materials Research, 1967
- A Comparison of the Tissue Reactions to Plastic MaterialsA.M.A. Archives of Surgery, 1957