An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry
- 1 May 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (5) , 1113-1132
- https://doi.org/10.1088/0031-9155/43/5/005
Abstract
BANG-gel dosimetry offers the potential for measuring the dose delivered by a radiotherapy treatment technique, in three dimensions, with high spatial resolution and good accuracy. The ability to measure comprehensively a 3D dose distribution is a major advantage of the gel dosimeter over conventional planar and point-based dosimeter devices, particularly when applied to the verification of complex dose distributions characteristic of intensity-modulated radiotherapy (IMRT). In this paper an in-house manufactured BANG-gel dosimeter was applied to study the dose distributions of two irradiation experiments for which the distributions were known: (i) a dosimetrically simple parallel-opposed irradiation, and (ii) a more complex nine-field 'static tomotherapy' intensity-modulated irradiation delivered with the Nomos MIMiC. The uniform distribution in (i) allowed a study of the magnetic resonance (MR) imaging parameters to achieve an optimal trade-off between noise and image resolution (optimum image resolution for the Siemens 1.5T Vision system was determined to be approximately 0.8 mm2 with a slice thickness of 2 mm). The spatial uniformity of gel sensitivity to radiation was found to depend strongly on the presence of oxygen, which must be eliminated for the gel dosimeter to be of use. The gel dosimeter was found to agree well with predicted dose distributions and accurately measured the steep penumbral fall-off of dose, even after many days, proving its potential for the verification of IMRT distributions. In the nine-field IMRT delivery (ii) the predicted dose was computed by both an in-house 'component-delivery' dose algorithm and the Peacock planning-system dose algorithm. Good agreement was found between the two algorithms despite the latter's omission of the change in penumbral characteristics with aperture-size during delivery, lack of inhomogeneity correction and approximate modelling of leaf leakage. These effects were found to be small for the problem studied. The predicted distribution agreed well with the gel-measured distribution at medium and high doses (50-90% isodose lines) although differences of up to 10% were observed at lower doses (30% isodose line). The gel dosimeter was found to have the potential to verify IMRT distributions but required considerable care to achieve accurate results. Attention was required to achieve uniformity of gel sensitivity (to prevent oxygen contamination), and in the calibration process.Keywords
This publication has 14 references indexed in Scilit:
- Abutment region dosimetry for sequential arc IMRT deliveryPhysics in Medicine & Biology, 1997
- Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of bang polymer gel dosimetersInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Dosimetry of high energy photon and electron beams with CEA filmsMedical Physics, 1996
- The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulationInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Diffusion in Fe(II/III) radiation dosimetry gels measured by magnetic resonance imagingPhysics in Medicine & Biology, 1995
- Clinical realization of 3D conformal intensity modulated radiotherapy: Regarding bortfeld et al., IJROBP 30:899–908; 1994International Journal of Radiation Oncology*Biology*Physics, 1995
- Peacock™: A system for planning and rotational delivery of intensity‐modulated fieldsInternational Journal of Imaging Systems and Technology, 1995
- Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeterPhysics in Medicine & Biology, 1994
- NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRIMagnetic Resonance Imaging, 1993
- Algorithm for dosimetry of multiarc linear-accelerator stereotactic radiosurgeryMedical Physics, 1991