Study of a Reagent- and Mediatorless Biosensor for D-Amino Acids Based on Co-Immobilized D-Amino Acid Oxidase and Peroxidase in Carbon Paste Electrodes
- 1 October 1993
- journal article
- research article
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 8 (2) , 146-173
- https://doi.org/10.1177/088532829300800204
Abstract
A biosensor for the analysis of D-amino acids is described. Carbon paste (graphite/paraffin oil) was chemically modified with immobilized D-amino acid oxidase and either horse-radish peroxidase or fungal peroxidase from Arthromyces ramosus. The two enzymes dissolved in buffer, together with an amine containing oligomer or polymer, were adsorbed on dry graphite. Prior to immobilization, the graphite was heat treated at 700°C for 15 s to promote an efficient electron transfer between graphite and the peroxidase. The mixture was dried before addition of the pasting liquid. The sensor is based on the fact that the hydrogen peroxide produced by the action of D-amino acid oxidase is electrocatalytically reduced through the action of the peroxidase. The amine containing compound acted as a stabilizer and activator of the enzymes in the paste. The enzyme electrode was investigated as a sensor for D-phenylalanine and hydrogen peroxide in a flow through electrochemical cell connected to a single line flow injection system. The influences on the response by different additives to the paste and pH are reported. Linear calibration curves were obtained between 0.1 and 1.4 mM for D-phenylalanine and 5 and 1000 μM for hydrogen peroxide at an applied potential of -50 mV vs. Ag/AgCl. The sensor was also active for the following D-amino acids: D-alanine, D-valine, D-leucine, D-isoleucine, D-serine, D-aspartic acid, D-glutamic acid, D-lysine, D-histidine, D-arginine, D-tryptophan, D-methionine, and D-proline.Keywords
This publication has 33 references indexed in Scilit:
- Mediatorless electrocatalytic reduction of hydrogen peroxide at graphite electrodes chemically modified with peroxidasesJournal of Biotechnology, 1993
- Carbon fibres as electrode materials for the construction of peroxidase-modified amperometric biosensorsAnalytica Chimica Acta, 1993
- Polyethyleneimine in immobilization of biocatalystsEnzyme and Microbial Technology, 1991
- Evaluation of D-amino acid levels in human urine and in commercial L-amino acid samplesAmino Acids, 1991
- Gas chromatographic detection of D-amino acids as common constituents of fermented foodsChromatographia, 1989
- Towards macromolecular recognition at electrodes: fast interfacial electron transfer to cytochrome c peroxidase at graphite electrodes is promoted by aminoglycosidesBiochemical Society Transactions, 1988
- Direct electrical communication between chemically modified enzymes and metal electrodes. 2. Methods for bonding electron-transfer relays to glucose oxidase and D-amino-acid oxidaseJournal of the American Chemical Society, 1988
- Fast interfacial electron transfer between cytochrome c peroxidase and graphite electrodes promoted by aminoglycosides: novel electroenzymic catalysis of hydrogen peroxide reductionJournal of the American Chemical Society, 1987
- Enzymatic determination of glucose in a flow system by catalytic oxidation of the nicotinamide coenzyme at a modified electrodeAnalytica Chimica Acta, 1985
- Enzyme HandbookPublished by Springer Nature ,1969