Accuracy of an Unattended Home CPAP Titration in the Treatment of Obstructive Sleep Apnea
- 1 July 2000
- journal article
- clinical trial
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 162 (1) , 94-97
- https://doi.org/10.1164/ajrccm.162.1.9908023
Abstract
Treatment of sleep apnea-hypopnea syndrome (SAHS) by fixed continuous positive airway pressure (CPAP) requires an in-laboratory titration procedure to determine the effective pressure level (Peff ). We recently reported that one auto-CPAP machine can be used without titration study allowing Peff determination. The aim of this study was to evaluate the accuracy of an auto CPAP trial at home. A 1- or 2-wk automatic CPAP trial was done at home in 40 patients by estimating the reference pressure (Pref ) to be set and a Pref + 3 cm H(2)O/-4 cm H(2)O pressure interval. Peff was then determined according to the percentage of CPAP time that was spent </= Pref. This Peff value was set on a fixed CPAP machine for two additional weeks and a control sleep study was done. The pressure setting on fixed CPAP had to be increased by 1 +/- 1 cm H(2)O (mean +/- SD) above estimated Pref. Sleep improved with fixed CPAP, with a normalization of the apnea + hypopnea index (AHI) in 38 of 40 and resumption of diurnal hypersomnolence. CPAP compliance remained excellent (CPAP use: 6.1 +/- 1.7 h/ night) after 6.5 +/- 2.8 mo of CPAP treatment. These results indicate that auto-CPAP therapy represents a new useful and accurate way to identify conventional CPAP setting outside hospital and sleep laboratories.Keywords
This publication has 17 references indexed in Scilit:
- Nasal pressure recording in the diagnosis of sleep apnoea hypopnoea syndromeThorax, 1999
- Automatic nasal continuous positive airway pressure titration in the laboratory: patient outcomesThorax, 1997
- Comparison of manual and automatic CPAP titration in patients with sleep apnea/hypopnea syndrome.American Journal of Respiratory and Critical Care Medicine, 1996
- Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome.American Journal of Respiratory and Critical Care Medicine, 1996
- Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome.American Journal of Respiratory and Critical Care Medicine, 1996
- Effects of mouth opening on upper airway collapsibility in normal sleeping subjects.American Journal of Respiratory and Critical Care Medicine, 1996
- Required levels of nasal continuous positive airway pressure during treatment of obstructive sleep apnoeaEuropean Respiratory Journal, 1994
- The Occurrence of Sleep-Disordered Breathing among Middle-Aged AdultsNew England Journal of Medicine, 1993
- Daytime Sleepiness, Snoring, and Obstructive Sleep ApneaChest, 1993
- Mortality and Apnea Index in Obstructive Sleep ApneaChest, 1988