Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imaging
- 1 April 1992
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 24 (2) , 343-357
- https://doi.org/10.1002/mrm.1910240215
Abstract
This investigation explores the feasibility of a catheter‐based receiver probe for NMR study of arterial walls. Simulations and phantom experiments demonstrate the spatial response of several “inside‐out” probe coil designs, including loop, “birdcage,” “multipole,” “center return,” and opposed solenoids. For a target defined by an annulus in a plane perpendicular to B0, the opposed solenoid design provides substantially superior homogeneity to other designs considered. Canine iliofemoral artery images were acquired using a catheter probe in a whole‐body, 1.5‐T clinical imaging system. In situ (cadaver) images acquired with TE 70, TR 2400,2‐mm slice thickness, and 78 × 78‐μm in‐plane voxel size in 10‐min acquisition times show vessel wall structures identified as intima, internal elastic lamina, media, and adventitia. In vivo images from similar acquisition conditions are much more poorly resolved, presumably due to motion, despite the use of cardiac gating and gradient moment nulling, so the feasibility of obtaining high‐resolution in vivo MR images of the arterial wall remains in doubt. © 1992 Academic Press, Inc.Keywords
This publication has 13 references indexed in Scilit:
- Significance of the point of expansion in interpretation of gradient moments and motion sensitivityJournal of Magnetic Resonance Imaging, 1991
- Chemical shift magnetic resonance imaging of human atheroma.Heart, 1989
- Chemical Shift Imaging of Atherosclerosis at 7.0 TeslaInvestigative Radiology, 1989
- High-resolution proton NMR spectra of human arterial plaqueBiochemical and Biophysical Research Communications, 1987
- Proton Relaxation Times in Arterial Wall and Atheromatous Lesions in ManInvestigative Radiology, 1986
- In vivo 31P nuclear magnetic resonance measurements in canine heart using a catheter-coil.Circulation Research, 1984
- Evaluation of NMR Imaging for Detection and Quantification of Obstructions in VesselsInvestigative Radiology, 1982
- Remote (inside-out) NMR. III. Detection of nuclear magnetic resonance in a remotely produced region of homogeneous magnetic fieldJournal of Magnetic Resonance (1969), 1980
- Sensitivity and performance time in NMR imagingJournal of Magnetic Resonance (1969), 1979
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance (1969), 1976